general Considerations
draft
Before you install and operate your Exception
woodburning insert, please read the entire contents of
this manual. Pay particular attention to the explana-
tion of draft and its effect on insert performance in
the Installation section. By following the installation and
operating guidelines, you will ensure proper draft and gain
maximum efficiency and enjoyment from your insert.
Fuel
Your Exception burns wood very efficiently. Here
are some guidelines concerning log size and moisture
content that will help you obtain the best performance.
Select hardwoods if possible, as they are heavier
and contain more heating capacity (BTU's) per load than
do softwoods. Wood should be split and stored under
cover for "seasoning"-a year is recommended. Your in-
sert is not an incinerator-do not burn garbage, painted or
treated wood, plastic, or other debris.
Keep the area around the insert free from clutter.
Keep all combustibles, including fuel, beyond the code-
required clearance distance (48" or 1215 mm in the U.S.,
1525 mm or 60" in Canada). Never store fuel in front of
the insert where it could interfere with door operation,
safe loading, and ash removal.
Do not burn garbage or flammable fluids
such as gasoline, naptha, or engine oil.
The Insert
doors
Your insert has a large glass-paneled door for
loading and fire viewing. To open the glass door, turn
the handle clockwise and pull out; to close the door,
return the handles to an open, 9 o'clock, position. Push
the door closed, while turning the handle counterclock-
wise to the 6 o'clock position.
If the latch on your Exception door needs adjust-
ment, follow the instructions given in the Maintenance
section of this manual.
FOR USE IN THE U.S. AND CANADA

Operation

The door must be closed while the insert is in nor-
mal operation, and the gaskets routinely examined for
wear and replaced when necessary. Good door seals are
important for maintaining control of the insert. Operat-
ing the insert with the door inadequately sealed, could
create a serious over-firing condition (discussed later in
this section).
The glass used in your Exception is manufactured
to exact standards to withstand the high heat of the fire.
Like all glass, it must be treated with common sense and
care. Never abuse the glass by slamming the door shut
or striking the glass with a heavy object. If the glass is
broken or damaged, do not operate the insert until it has
been replaced (See instructions in the Maintenance sec-
tion.)
Operating As A Fireplace
To operate as a fireplace, open the damper and keep
it open. Next, open the door and place the optional screen
(part number 3-40-727336) over the door opening. Check
for smoke spillage into the room. If smoke is escaping into
the room, remove the screen and close the door. Always
wear gloves when placing or removing the screen.
Never leave the unit unattended with the
door open.
Andirons
The andirons keep the fuel from coming in direct
contact with the glass, and keep hot coals and embers from
spilling out while reloading. Never build a fire directly
against the glass.
Do not use a grate or elevate the fire. Build the fire
directly on the insert's brick hearth.
Cette guide d'utilisation est disponible en
francais
Chez votre concessionnaire de harman
Stove Company
SAFETY NOTICE: IF THIS HARMAN EXCEP-
TION MODEL F200 INSERT IS NOT PROPERLY
INSTALLED, A HOUSE FIRE MAY RESULT.
FOR YOUR SAFETY, FOLLOW INSTALLATION
DIRECTIONS. CONTACT LOCAL BUILDING
OR FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTION REQUIRE-
MENTS IN YOUR AREA.