Goldstar HBLG5004 Service Manual page 18

Room air conditioner
Table of Contents

Advertisement

Disassembly
Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment, pinch-off tool capable
of making a vapor proof seal, leak detector, tubing cutter, hand tools to remove components and service valve.
CONDENSER
(HIGH PRESSURE SIDE)
B
Figure 31A-Pulling Vacuum
18 Room Air Conditioner
COMPRESSOR
A
EXTERNAL VACUUM PUMP
COMPOUND GAUGE
MANIFOLD
GAUGE
EVAPORATOR
(LOW PRESSURE SIDE)
CAPILLARY TUBE
LO
HI
CHARGING CYLINDER
A
B
Figure 31B-Charging
B
A
SEE INSETS
BELOW
C