ROBERT SHAW HEAT PUMP THERMOSTAT CONVERSION TO LENNOX
HP21 WITH CB21 PCB HEAT PUMP SYSTEMS
24 VAC, RETURN
R-VR
COMPRESSOR CONTACTOR
Y1
REVERSING VALVE [COOLING MODE]
O
FAN CONTACTOR CIRCUIT
F
EMERGENCY HEATING CIRCUIT
E
2ND. STAGE HEATING CIRCUIT
W1
L
24 VAC, COMMON
X
Y2
THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR
FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS
ROBERT SHAW HEAT PUMP THERMOSTAT CONVERSION TO LENNOX
HP22 WITH CB19 PCB HEAT PUMP SYSTEMS
24 VAC, RETURN
R-VR
COMPRESSOR CONTACTOR
M
REVERSING VALVE [HEATING MODE]
R
FAN CONTACTOR CIRCUIT
F
EMERGENCY HEATING CIRCUIT
E
2ND. STAGE HEATING CIRCUIT
Y
SYSTEM MONITOR LED
L
24 VAC, COMMON
X
2ND. STAGE COOLING CIRCUIT
Y2
THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR
FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS
ROBERT SHAW HEAT PUMP THERMOSTAT
R
O
Y1
B
ROBERT SHAW HEAT PUMP THERMOSTAT
R
Y1
O
B
15
W2
G
E
L
W2
G
E
L
Y2
C
C
Y2

Hide quick links: