1 heat / 1 cool digital non-programmable thermostat (13 pages)
Summary of Contents for Robertshaw 9600
Page 1
All manuals and user guides at all-guides.com 9600 DIGITAL PROGRAMMABLE THERMOSTAT ® ™ I N T E G R A T E D C O M F O R T S O L U T I O N S ELECTRIC...
Page 2
All manuals and user guides at all-guides.com Features • Four setpoints for weekday programming—two setpoints for weekend comfort. • Two AA ENERGIZER brand batteries retain program memory even during power outages. • Low battery indicator. • Fahrenheit/Celsius display option. • Programmable from 45°F (4°C) to 90°F (32°C). •...
Page 3
All manuals and user guides at all-guides.com Figure 1 Installing Item 9600 Thermostat NOTE: F , 4-5 OR NEW INSTALLATIONS MOUNT THERMOSTAT ON AN INSIDE WALL FEET ABOVE THE FLOOR O NOT INSTALL BEHIND A DOOR IN A CORNER NEAR AIR VENTS...
All manuals and user guides at all-guides.com Figure 3 MOUNTING HOLES PROG MORN DAY EVE NITE CHANGE AUTO/MAN Elec COOL OFF HEAT FAN AUTO ON 7. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plastic anchors do not require a drilled hole for drywall. 8.
All manuals and user guides at all-guides.com 13. Install two AA ENERGIZER brand batteries or equivalent into battery compartment. Be sure to match positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. The display will show as follows: 14.
All manuals and user guides at all-guides.com 3. Press Press SET P to change temperature differential* 1°. T EMPERATURE IFFERENTIAL IS ACTORY PRESET AT HIS MEANS THAT WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM THE TEMPERATURE SETTING THE SYSTEM WILL TURN ON F THE SYSTEM TURNS ON TOO OFTEN...
Page 7
All manuals and user guides at all-guides.com 4. Press SET. SET PR PROG SET PROG/MAN COOL-OFF-HEAT AUTO - ON 5. Press to change MORN temperature. 6. Repeat Steps 2-5 for DAY, EVE, and NITE. COOL-OFF-HEAT 7. Shift COOL-OFF-HEAT switch to HEAT position.
All manuals and user guides at all-guides.com Temporary Program Override To temporarily increase or decrease temperature: Press PROG SET PROG/MAN COOL-OFF-HEAT AUTO - ON The thermostat will automatically return to the program at the next scheduled setting change. Manual Operation 1.
Page 9
All manuals and user guides at all-guides.com To Test Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY. CAUTION: D 50°F O NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE IS BELOW (10°C).
All manuals and user guides at all-guides.com Troubleshooting Symptom Remedy Thermostat does not turn Check wiring. on system. (See INSTALLATION) Check fuse. Replace with 2 amp Slo-Blo fuse if fuse has opened. Thermostat turns on and off too Increase temperature differential. frequently.
All manuals and user guides at all-guides.com Wiring Diagrams The following is just a sample of the most common types of HVAC sys- tems. Refer to your system’s installation manual for wiring information. HEAT ONLY HEAT/COOL 4-WIRE 3-WIRE SINGLE TRANSFORMER SINGLE TRANSFORMER Factory-Installed Factory-Installed...
Maple Chase Company warrants to the original contractor installer or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from date of purchase. This warranty...