Air Flow Data; Dip Switches - Goodman VC8 Installation Instructions Manual

Mvc8 & dvc8 series gas furnace
Table of Contents

Advertisement

A
F
D
IR
LOW
ATA
Speed Selection Dip Switches
Cool
Selection
Switches
TAP
1
2
A
OFF
OFF OFF OFF
B
ON
OFF
C
OFF
ON OFF
D
ON
ON
Profiles
Pre-Run
A
-------
B
-------
C
-------
D
30 sec/50%
To set airflow:
(1) Select model and desired
high stage cooling airflow. Determine the corresponding tap
( A, B, C, or D ). Set dip switches 1 and 2 to the appropriate
ON / OFF positions. (2) Select model and desired high stage
heating airflow. Determine the corresponding tap ( A, B, C, or
D ). Set dip switches 7 and 8 to the appropriate ON / OFF
positions. (3) Select the airflow adjustment factor taps A and
D are 1; Tap B is +10%; Tap C -10%. Set dip switches 3 and 4
to the appropriate ON / OFF positions.
To set Comfort Mode:
(see profiles above). Set switches 5 and 6 to the appropriate
ON / OFF positions.
NOTE: Airflow data shown applies to non-communicating mode operation only. For a fully communicating
system, please see the outdoor unit's installation instructions for cooling and pump heating airflow data. See
ComfortNet™ System - Airflow Consideration section for details.
D
S
IP
WITCHES
Switch
Purpose
Bank
He at OFF
De lay
S1
The rmo sta t
Setup
Bu s B IAS
S2
TERM
Bus Te rmin ation
Co oling
Spee d Tap
S3
A djust Taps
Ra mping
Pro fi les
S4
Hea ting
Spee d Tap
S5
DEHUM
---
Not ap plica ble
Adjust
Profile
Heat
Selection
Selection
Selection
Switches
Switches
Switches
3
4
5
6
7
8
OFF OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
Short-Run
OFF Delay
--------
60 sec/100%
30 sec/50%
60 sec/100%
7.5 min/82%
60 sec/100%
7.5 min/82%
30 sec/50%
Select desired Comfort Mode profile
Function
1
9 0 secon ds
OFF
OFF
120 se cond s
ON
OFF
150 se cond s*
OFF
ON
180 se cond s
ON
ON
1 -Stage T-stat
---
2-S ta ge T-S ta t
---
5 -Min Delay
---
Auto Del ay
---
BIA S
ON*
ON*
---
A
OFF
OFF
B
ON
OFF
C
OFF
ON
D*
ON
ON
No rma l*
---
1 0%
---
-10%
---
No rmal
---
A*
---
B
---
C
---
D
---
A
---
B*
---
C
---
D
---
Disa ble d*
---
E na bled
---
Model
Tap
A
B
*DVC80603B***
C
D
A
B
*DVC80805C***
C
D
A
B
*DVC81005C***
C
D
A
*MVC80604B***
B
C
D
A
B
*MVC80805C***
C
D
A
*MVC81005C***
B
C
D
DIP Swi tch No.
2
3
4
5
---
---
---
---
---
---
---
---
---
---
---
---
---
OFF
---
---
---
ON
---
---
---
---
OFF
---
---
---
ON
---
---
---
---
---
ON*
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
OFF
OFF
---
---
ON
OFF
---
---
OFF
ON
---
---
ON
ON
---
---
---
---
OFF
---
---
---
ON
---
---
---
OFF
---
---
---
ON
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
(*Indi cates fa cto ry se ttin g)
45
Low Stage High Stage Low Stage High Stage
Cool
Cool
Heat
390
600
735
520
800
805
650
1000
875
780
1200
935
800
945
520
715
1100
1015
910
1400
1085
1170
1800
1155
553
850
1085
748
1150
1155
943
1450
1225
1203
1850
1260
600
875
390
520
800
945
715
1100
1015
910
1400
1085
520
800
1050
715
1100
1120
910
1400
1190
1170
1800
1260
800
1210
520
715
1100
1225
910
1400
1245
1175
1800
1260
6
7
8
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
- --
---
---
OFF
---
---
OFF
---
---
ON
---
---
ON
---
---
- --
OFF
OFF
- --
ON
OFF
- --
OFF
ON
- --
ON
ON
- --
---
---
- --
---
---
Heat
1050
1150
1250
1350
1350
1450
1550
1650
1550
1650
1750
1800
1250
1350
1450
1550
1500
1600
1700
1800
1725
1750
1775
1800
9
10
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
- --
---
OFF
Un used
ON
Un used

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvc80603bDvc80805cDvc81005cMvc80604bMvc80805cMvc81005c

Table of Contents