Planet FNSW-1600P User Manual page 15

16-port 10/100mbps poe fast ethernet switch
Hide thumbs Also See for FNSW-1600P:
Table of Contents

Advertisement

POWER SOURCING
EQUIPMENT (PSE)
+ / -
+ / -
48V
The data pairs are used. Since Ethernet pairs are transformer coupled at each
end, it is possible to apply DC power to the center tap of the isolation transformer
without upsetting the data transfer. In this mode of operation the pair on pins 3
and 6 and the pair on pins 1 and 2 can be of either polarity.
POWER SOURCING
EQUIPMENT (PSE)
+ / -
+ / -
48V
4
5
SPARE PAIR
1
TX
2
SIGNAL PAIR
3
RX
6
SIGNAL PAIR
7
8
SPARE PAIR
Figure 1 - Power Supplied over the Spare Pins
4
5
SPARE PAIR
1
TX
2
SIGNAL PAIR
3
RX
6
SIGNAL PAIR
7
8
SPARE PAIR
Figure 2 - Power Supplied over the Data Pins
POWERED DEVICE
(PD)
4
5
1
RX
2
DC / DC
3
Converter
Converter
TX
6
7
8
POWERED DEVICE
(PD)
4
5
1
RX
2
DC / DC
3
Converter
TX
6
7
8
15