Planet FNSW-1608PS User Manual

Planet FNSW-1608PS User Manual

16-port 10/100mbps with 8-port poe web smart ethernet switch
Hide thumbs Also See for FNSW-1608PS:

Advertisement

16-Port 10/100Mbps with 8-Port PoE
Web Smart Ethernet Switch
FNSW-1608PS
User's Manual
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Planet FNSW-1608PS

  • Page 1 16-Port 10/100Mbps with 8-Port PoE Web Smart Ethernet Switch FNSW-1608PS User’s Manual - 1 -...
  • Page 2: Fcc Warning

    Trademarks Copyright © PLANET Technology Corp. 2006. Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose.
  • Page 3: Table Of Contents

    3.2.2 Web Management........................... 11 3.3 A IP A ....................11 SSIGNING AN DDRESS TO THE WITCH 3.4 L FNSW-1608PS ....................... 12 OGGING ON TO THE 4. CONSOLE INTERFACE..........................13 4.1 CONNECT TO PC ..........................13 4.2 L ..............................14 OGIN IN 4.3 M ..........................
  • Page 4: Introduction

    1. INTRODUCTION 1.1 Checklist Check the contents of your package for following parts: FNSW-1608PS x1 User's manual CD x1 Quick installation guide x1 Power cord x 1 RS232 cable x1 Rubber feet x 4 Two rack-mounting brackets with attachment screws x1...
  • Page 5: Features

    Auto-MDI/MDI-X detection on each RJ-45 port EMI standards comply with FCC, CE class A 1.4 Specification Model FNSW-1608PS Network Connector 16-Port RJ-45 for 10/100TX, 8-Port with PoE injector function LED Display One power, 1-8 port PoE in-use, LNK/ACT, 100, 9-16 port LNK/ACT, 100...
  • Page 6 IEEE 802.1p QoS - 6 -...
  • Page 7: Hardware Description

    Lights to indicate the port is running in 100Mbps speed. 2.2 Rear Panel The rear panel of the FNSW-1608PS indicates an AC inlet power socket, which accepts input power from 100 to 240V AC, 50-60Hz, and 1A max. And one console port at rear panel for switch management.
  • Page 8: Hardware Installation

    2.3 Hardware Installation This part describes how to install your Web Smart Ethernet Switch and make connections to the Switch. Please read the following topics and perform the procedures in the order being presented. To install your Switch on a desktop or shelf, simply completed the following steps.
  • Page 9 2.3.3 As a department / workgroup PoE Switch Providing up to 8 PoE, in-line power interface, the FNSW-1608PS can easily build a power central-controlled IP phone system, IP Camera system, AP group for the enterprise. For instance, 8 camera / AP can be easily installed around the corner in the company for surveillance demands or build a wireless roaming environment in the office.
  • Page 10: Switch Management

    - Assigning an IP address to the FNSW-1608PS - Logging on to the FNSW-1608PS 3.1 Overview The FNSW-1608PS provides a user-friendly, command line under console interface. Using this interface, you can perform various switch configuration and management activities, including: Command...
  • Page 11: Management Methods

    The serial port of the Switch default setting is set to 19200 baud using a character format of 8 data bits, no parity, and 1 stop bit. Therefore, configure the terminal or workstation to use these settings before you log on to the FNSW-1608PS. You can change this default setting, if desired, after you log on.
  • Page 12: Logging On To The Fnsw-1608Ps

    3.4 Logging on to the FNSW-1608PS When you log on to the FNSW-1608PS console port for the first time, a sign-on string appears and you are prompted for a console login user name and password. The factory default login username is admin without password.
  • Page 13: Console Interface

    RS-232 serial cable Use the bundled RS-232 serial cable and attach the 9-pin female connector to the male connector on the FNSW-1608PS. Plug the other side of this cable to your PC. Hyper Terminal In Windows 98/2000/ME/XP, launch “HyperTerminal”, create a new connection, and adjust settings as below:...
  • Page 14: Login In

    "admin" without password. You may change the password by use “set pass” command. Please always enter the correct user name and password. (See Figure 4-2) Figure 4-2 FNSW-1608PS login screen 4.3 Main Menu screen After login the FNSW-1608PS, the main menu screen shows as below. Figure 4-3 FNSW-1608PS Main Menu screen - 14 -...
  • Page 15: Getting Started

    4.4 Getting Started 4.4.1 General Guidelines The FNSW-1608PS allows users to configure the device via command line under console interface. Please type “help” or “?” for all available commands in the”FNSW-1608PS>” prompt. The screen of available commands in Figure 4-4 pears, and the detail description shown in table 4-1.
  • Page 16: Show Command

    Set IP xxx.xxx.xxx.xxx, mmm. mmm, mmm, mmm, Assign IP address, subnet mask, gateway of FNSW-1608PS. ggg.ggg.ggg.ggg Set Pass Change the default password of FNSW-1608PS, the maximum length is 4 characters. Factory Default Reset the FNSW-1608PS to factory default mode. Reboot Reboot the FNSW-1608PS.
  • Page 17 Show priority: Please refer to chapter 4.4.2.11 4.4.2.1 Show port[n] / all Display the status on each port of FNSW-1608PS, these two commands allows you to view the port status of the Switch and the correct usage is shown as below: Show port [n]: n=1-16, to view per port status of FNSW-1608PS.
  • Page 18 4.4.2.2 Show vlan[n] Display one specific VLAN group status of FNSW-1608PS, the correct usage is shown as below: Show vlan [n]: n=1-16, to view one specific VLAN group status of FNSW-1608PS, the VLAN group status screen in Figure 4-8 appears.
  • Page 19 Figure 4-9 appears. Figure 4-9 Trunk group status screen 4.4.2.4 Show ip Display the current IP address, netmask and gateway of FNSW-1608PS, the IP subnet address information screen in Figure 4-10 appears. Figure 4-10 IP subnet address information screen - 19 -...
  • Page 20 Figure 4-11 System information screen 4.4.2.6 Show poe status [n] Display the poe link status on each port of FNSW-1608PS, this command allows you to view per poe port link status of the Switch and the correct usage is shown as below: Show poe status [n]: n=1-8, to view per poe port link status of FNSW-1608PS.
  • Page 21 4.4.2.7 Show poe [n] Display the poe status on each port of FNSW-1608PS, this command allows you to view per poe port status of the Switch and the correct usage is shown as below: Show poe [n]: n=1-8, to view per poe port status of FNSW-1608PS. The per poe port status screen in Figure 4-13 pears.
  • Page 22 Display the current vlan mode of FNSW-1608PS, the vlan mode display screen in Figure 4-15 appears. Figure 4-15 Display VLAN mode screen 4.4.2.10 Show pvid Display the current per port pvid of FNSW-1608PS, the per port pvid display screen in Figure 4-16 appears. Figure 4-16 Display pvid screen - 22 -...
  • Page 23: Set Command

    4.4.2.11 Show priority Display the current priority status of FNSW-1608PS, the priority status display screen in Figure 4-17 appears. Figure 4-17 Display priority screen 4.4.3 Set command From the main menu screen (see Figure 4-3), input “set” and press enter. The set command list screen in Figure 4-18 appears.
  • Page 24 4.4.3.1 Set port [n] This command allows configuring per port parameters of FNSW-1608PS. the correct usage is shown as below: Set port [n]: n=1-16, to configuring per port parameters of FNSW-1608PS. The configuring per port parameters screen in Figure 4-19 appears and the detail description shown in table 4-2.
  • Page 25 Allow assign low queue or high queue on each port. Table 4-2 Descriptions of the Port Configuration screen Objects 4.4.3.2 Set trunk This command allows disable or enable trunk function of two ports or four ports from FNSW-1608PS. The trunk function setting screen in Figure 4-20...
  • Page 26 4.4.3.4 Set poe [n] This command allows configuring per poe port parameters of FNSW-1608PS. the correct usage is shown as below: Set poe [n]: n=1-8, to configuring per poe port parameters of FNSW-1608PS. The configuring per poe port parameters screen in Figure 4-22 appears and the detail description shown in table 4-3.
  • Page 27 Assign POE power provision priority (0-3) to each POE port. Table 4-3 Descriptions of PoE port Configuration screen Objects 4.4.3.5 Set management vlan This command allows assign one VLAN as management VLAN of FNSW-1608PS. Only the assigned VLAN group can manage The management vlan function setting screen in...
  • Page 28 4.4.3.6 Set vlan mode This command allows disable or enable port-based vlan function of FNSW-1608PS, the vlan mode setting screen in Figure 4-24 appears Figure 4-24 VLAN mode Configuration screen 4.4.3.7 Set pvid This command allows assign PVID of each port from FNSW-1608PS, the PVID setting screen in Figure 4-25 appears.
  • Page 29 4.4.3.8 Set priority This command allows set priority function of FNSW-1608PS; the available options are TCP/IP TOS/DS Priority Disable or Enable, 802.1p Priority Disable or Enable, Queue Service Rate (4:1, 8:1, 16:1, N). The priority setting screen in Figure 4-26 appears.
  • Page 30 4.4.3.9 Set ip xxx.xxx.xxx.xxx.mmm.mmm.mmm.mmm.ggg.ggg.ggg.ggg This command allows assign IP address, netmask and gateway of FNSW-1608PS. the correct usage is shown as below: set ip 192.168.0.1 255.255.255.0 192.168.0.254 and press <Enter> If the IP is successfully configured, the switch will automatically restart as the following screens. After reboot the Switch and power on completed, you can use the new IP address access of FNSW-1608PS.
  • Page 31 4.4.3.10 Set pass This command allows assign password of FNSW-1608PS. The password setting screen in Figure 4-29 appears. Figure 4-29 Password configuration screen Notice: For security reason, please change and memorize the new password after this first setup. The maximum length is 4 characters.
  • Page 32: Factory Default

    4.4.4 Factory default This command allows rest FNSW-1608PS to factory default mode. The factory default screen in Figure 4-30 & 4-31 pears. Figure 4-30 Factory default screen Figure 4-31 Factory default screen - 32 -...
  • Page 33: Reboot

    4.4.5 Reboot This command allows reboot FNSW-1608PS, the reboot screen in Figure 4-32 & 4-33 appears. Figure 4-32 Switch reboot screen Figure 4-33 Switch reboot screen - 33 -...
  • Page 34: Logout

    4.4.6 Logout This command provides logout the FNSW-1608PS, the screen in Figure 4-34 appears. Figure 4-34 FNSW-1608PS Logout screen - 34 -...
  • Page 35: Web Management

    Before login the Web interface of FNSW-1608PS, please setup the “IP Address” with local serial console port (RS232 port) and use this IP address to configure FNSW-1608PS through the Web interface. Or modify your PC’s IP domain to the same with FNSW-1608PS then use the default IP address (192.168.0.100) to remote configure FNSW-1608PS through the Web interface.
  • Page 36: Port Status

    Figure 5-2 The web main menu screen of FNSW-1608PS 5-2 Port Status This section provides current status of each port from FNSW-1608PS, the screen in Figure 5-3 appears and Table 5-1 describes the port status object of switch. Figure 5-3 FNSW-1608PS Port Status Web Page screen...
  • Page 37: Port Setup

    Display half or full duplex mode of each port on FNSW-1608PS. Flow Control Display the flow control Disable or Enable state of each port on FNSW-1608PS. Auto Negotia- Display the Auto negotiation Disable or Enable state of each port on FNSW-1608PS.
  • Page 38: Vlan Setup

    A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows you to isolate network traffic so only members of the VLAN receive traffic from the same VLAN members. The FNSW-1608PS supports port-based VLAN function. In the default configuration with VLAN disable, the screen in Figure 5-5 appears.
  • Page 39: Vlan Setting Example

    Figure 5-6 FNSW-1608PS port-based VLAN Setting Web Page screen Figure 5-7 FNSW-1608PS port-based VLAN Setting Web Page screen 5.4.1 VLAN setting example: VLAN scenario 1. Port 16 is the file server port for all the workstations 2. Port 1 to port 15 is different devices that do need to see each other Setup steps 1.
  • Page 40: Port Trunk Setup

    After turn on the port trunk feature, port 1 and port 2 or port 13,14,15,16 should connect to another switch, such as another FNSW-1608PS, that also supports port trunk feature to double the bandwidth in between. Otherwise, if the connected switch do not support port trunk, it will cause network loop and hangs the whole network.
  • Page 41: Misc Configuration

    Allow user to change the password and maximum up to 4 characters, please refer to chapter 5.6.2 Restore System Default Allow user to reset the FNSW-1608PS to factory default mode, please refer to chapter 5.6.3 Reboot System Allow user to reboot the FNSW-1608PS, please refer to chapter 5.6.4...
  • Page 42: System Information

    Allow user to select queue service rate and available options are 4:1, 8:1, 16:1, N. The screen in Figure 5-12 appears. Default is 16:1. IP Address Allow user to assign new IP address of FNSW-1608PS, after setup completed. Please press “Apply” button and switch will reboot automatically to take effect. Subnet Mask Allow user to assign new Subnet Mask of FNSW-1608PS, after setup completed.
  • Page 43 Figure 5-11 FNSW-1608PS Management VLAN options Web Page screen Figure 5-12 FNSW-1608PS Queue service rate options Web Page screen - 43 -...
  • Page 44: Password / Access Setting

    5.6.2 Password / Access Setting This section provides password change Configuration of FNSW-1608PS, please input the old password in “Password” space and input the new password in “New Password” space. After setup completed, please press “Submit” button to take effect and the switch will logout automatically. Please login web interface with new password, the screen in Figure 5-13 &...
  • Page 45: Restore System Default

    Figure 5-15 The FNSW-1608PS login Web Page screen 5.6.3 Restore System Default This section provides reset FNSW-1608PS to factory default mode, after choose this function and the following screen appears in Figure 5-16. Please press “OK” button to take effect and the switch will reboot automatically and ask you to re-login web interface with default username “admin”...
  • Page 46 Figure 5-17 The FNSW-1608PS rebooting Web Page screen Figure 5-18 FNSW-1608PS Re Login Web Page screen - 46 -...
  • Page 47: Reboot System

    Figure 5-19 The FNSW-1608PS login Web Page screen 5.6.4 Reboot System This section provides reboot FNSW-1608PS, after choose this function and the following screen appears in Figure 5-20. Please press “OK” button to take effect and the switch will reboot and ask you to re-login web interface with correct username “admin”...
  • Page 48 Figure 5-21 The FNSW-1608PS rebooting Web Page screen Figure 5-22 FNSW-1608PS Re Login Web Page screen - 48 -...
  • Page 49: Firmware Upgrade

    Figure 5-23 The FNSW-1608PS login Web Page screen 5.6.5 Firmware Upgrade This section provides firmware upgrade of FNSW-1608PS, after choose this function and the following screen appears in Figure 5-24. Please press “Update” button to continue following firmware upgrade process.
  • Page 50 Figure 5-25 The FNSW-1608PS firmware upgrade Web Page screen Please press “Browser” to locate the latest firmware of FNSW-1608PS that deposit in your PC and press “Upgrade” to start the firmware upgrade process. The screen in Figure 5-26 appears. Figure 5-26 The FNSW-1608PS firmware upgrade Web Page screen...
  • Page 51 Figure 5-27 The FNSW-1608PS firmware upgrade Web Page screen Then the re-login screen appears in Figure 5-28, please press “Re Login” button to re-login web interface of FNSW-1608PS with latest firmware version, the screen in Figure 5-29 appears. Figure 5-28 The FNSW-1608PS firmware upgrade Web Page screen...
  • Page 52 Figure 5-29 The FNSW-1608PS login Web Page screen Notice: Please does not power off the FNSW-1608PS during firmware upgrade process. - 52 -...
  • Page 53: Poe

    5-7 POE This section provides POE status and POE configuration of FNSW-1608PS, the POE Status screen in Figure 5-30 appears and Table 5-5 describes the POE status object of FNSW-1608PS. Figure 5-30 FNSW-1608PS POE Status Web Page screen Object Description Port Indicate port 1 to port 8.
  • Page 54 The POE Configuration screen in Figure 5-31 appears and Table 5-6 describes the POE Configuration object of switch. After setup completed, please press “Apply” button to take effect. Figure 5-31 FNSW-1608PS POE Configuration Web Page screen Object Description Port Indicate port 1 to port 8.
  • Page 55: Logout

    5-8 Logout This section allows to logout the FNSW-1608PS, the screen in Figure 5-32 & 5-33 appears. Figure 5-32 FNSW-1608PS Logout Web Page screen Figure 5-33 The FNSW-1608PS login Web Page screen - 55 -...
  • Page 56: Switch Operation

    No packet loss will occur. 6.5 Auto-Negotiation The STP ports on the FNSW-1608PS switch have built-in "Auto-negotiation". This technology automatically sets the best possible bandwidth when a connection is established with another network device (usually at Power On or Reset).
  • Page 57: Troubleshooting

    Why I connect my PoE device to FNSW-1608PS and it cannot power on? Solution: Please check the cable type of the connection from FNSW-1608PS (port 1 to port 8) to the other end. The cable should be an 8-wire UTP, Category 5 or above, EIA568 cable within 100 meters.
  • Page 58: Appendix A Networking Connection

    APPENDIX A NETWORKING CONNECTION A.1 Switch‘s RJ-45 Pin Assignments Contact MDI-X 1 (TX +) 2 (TX -) 3 (RX +) 6 (RX -) 4, 5, 7, 8 Not used Not used A.2 RJ-45 cable pin assignment There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection: Figure A-1: Straight-Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the...

Table of Contents