Connection; Using Coaxial Communications - Samsung SCO-2081R Series User Manual

High resolution weatherproof ir camera
Hide thumbs Also See for SCO-2081R Series:
Table of Contents

Advertisement

Connection

(1) Connection to a PC.
Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable.
EX) SERIAL PORT OF THE PC(COM1)
RS-485 CONTROL CABLE
(2) Connection to a DVR or System Controller.
Connect the RS-485 cable to the connection ports of the DVR or System Controller.
485 Control Board Connection Port
(+) CONNECTION TERMINAL
(-) CONNECTION TERMINAL
RS-485 Communication establishment initial value.
Item
Initial value
When making a control system to control the camera, please use to the protocol SAMSUNG-T,
SAMSUNG-E, PELCO-D , PELCO-P, BOSCH, HONEYWELL, VICON, PANASONIC, GE, AD.
When you connecting to RS-485 CONTROL TERMINAL, please peel off the outer skin inside the
RS-485 CONTROL TERMINAL.
BLUE (ALARM OUT)
GRAY (EXT _ D/N IN) You can switch to Day&Night Mode by connecting an external
BLACK (GND)
:
Used for earth-grounding.

USING COAXIAL COMMUNICATIONS

• Coaxial Communications System
• OSD Control method
CAMERA
SET
UP
DOWN
LEFT
RIGHT
16_ Connection
Camera ID
BAUD RATE
1
9600
Used to connect the alarm output signal.
:
:
signal to this terminal.
MENU/ENTER
UP KEY
DOWN KEY
LEFT KEY
RIGHT KEY
SERIAL CABLE
RS-485 CONVERTER
RS-485 Control Port
(485+)
(485-)
UART MODE
8-N-1
DVR
RET PKT
ENABLE
CONTROLLER
OSD KEY
JOYSTICK UP
JOYSTICK DOWN
JOYSTICK LEFT
JOYSTICK RIGHT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scv-2082rSco-2081rnSco-2081rp

Table of Contents