server path for the configuration file. It needs to be set to a valid URL, either in FQDN or IP address format.
The "Config Server Path" can be the same or different from the "Firmware Server Path".
A configuration parameter is associated with each particular field in the web configuration page. A
parameter consists of a Capital letter P and 2 to 3 (Could be extended to 4 in the future) digit numeric
numbers. i.e., P2 is associated with the "Admin Password" in the Web GUI->Settings->Advanced Settings.
For a detailed parameter list, please refer to the corresponding firmware release configuration template.
When a Grandstream Devices boots up or reboots, it will issue a request for a configuration XML file
named "cfgxxxxxxxxxxxx.xml" followed by a file named "cfgxxxxxxxxxxxx", where "xxxxxxxxxxxx" is the
MAC address of the device, i.e., "cfg000b820102ab". The configuration file name should be in lower case
letters.
For more details on XML provisioning, please refer to:
http://www.grandstream.com/general/gs_provisioning_guide_public.pdf