Problem
Salty tasting water
after installation
Resin beads showing
up in drinking water
and sink
Sounds you might hear
Water has air bubbles
and is cloudy
Error Code on control
Possible Causes
Insufficient backwash and
rinse time
Low water pressure
Restricted drain hose
Cracked distributor
Running water from the unit into
a drain
Air in system after installation
Wiring may have worked loose in
control
What To Do
•Increase backwash time. See the Service: Regeneration
and Heavy Duty Backwash section.
•Check pressure; should be minimum 20 psi.
•Clean and reconnect hose.
•Call for service.
•This is normal.
•Will go away after it runs for a while.
•Unplug transformer.
•Remove control cover, release clips on side.
•Check for loose/incorrect wiring connections to electronic
board or switch. Reconnect as required.
•Reassemble control cover.
•Plug in Transformer.
•Wait six minutes for Error Code to reappear.
•If Error Code reappears call for service.