GE PNSF39Z01 Owner's Manual & Installation Instructions page 18

Profile performance series
Hide thumbs Also See for PNSF39Z01:
Table of Contents

Advertisement

About water softener system.
On
LAST RECHARGE
WATER MANAGEMENT SYSTEM
Turbine
Switch
Turbine
count
Valve
Minutes of cycle
position
remaining
Fill
TIME
WATER MANAGEMENT SYSTEM
Turbine
RECHARGE
WATER MANAGEMENT SYSTEM
x 10
DAY
18
Service: Manually Initiated Electronic Diagnostics
To enter diagnostics, press and hold the DATA button until the display appears as shown.
1
NOTE: If the softener is in the middle of a regeneration, top part of the display shows the cycle
of regeneration and minutes of the cycle remaining. If two cycle names are flashing, the valve
is in transition between the cycles.
A The three digits under WATER MANAGEMENT SYSTEM indicate water meter operation
as follows:
000 (steady) = soft water not in use...no flow through the meter.
—OPEN A NEARBY SOFT WATER FAUCET—
000 to 140 (continual) = repeats display for each gallon of water passing through the meter.
If you don't get a reading in the display, with faucet open, pull the sensor from the valve outlet
port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the
display. If you get a reading, shut off water supply, unhook the in and out plumbing and check the
turbine for binding.
B This display segment (
Use the TOUCH or HOLD button to manually advance the valve into each cycle and check correct
switch operation.
CORRECT SWITCH
DISPLAYS
Press the DATA button again. This diagnostic display shows the total number of recharges (top)
2
since the timer was connected to electrical power.
The number of days since the timer was connected to electrical power is shown in the bottom part
of the display. If over 1999 days, a (x10) indicator shows, meaning you must multiply the number
shown by 10.
Press DATA once again to return the present time to the display.
3
Motor
Position
switch
Valve
outlet
), in the following chart, indicates an open POSITION switch.
VALVE CYCLE STATUS
Valve in service, fill, brining, backwash
or fast rinse position.
Valve rotating from one position to another.
Sensor
housing
Turbine
Turbine
support
& shaft

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents