About water softener system.
DATA
REMAINING CAPACITY
FLOW RATE GPM
GALLONS TODAY
AVG. DAILY GALLONS
16
Feature/Service: Automatic Electronic Diagnostics
The timer computer has a self-diagnostic function for the electrical system (except input power and
water meter). The computer monitors the electronic components and circuits for correct operation.
If a malfunction occurs, an error code appears in the timer display.
The chart on Error Codes shows the error codes that could appear and possible defects for each code.
While an error code is displayed, the TOUCH or HOLD and DATA buttons remain operable so you can
perform the Manually Initiated Electronic Diagnostics.
ERROR CODE DISPLAYED ERR 01
POSSIBLE DEFECT
• motor
inoperative
• wiring harness • timer
or connection
to switch
• position switch
• timer (PWA)
To remove an error code: (1) Unplug transformer.
(2) Correct defect.
(3) Plug transformer in.
(4) Wait for at least 6 minutes. The error code will return if the reason
Feature: Other Data Displays
By continuing to press the DATA button, you can scan through four displays of operational
information. This data appears in the bottom portion of the display area.
REMAINING CAPACITY —
Immediately after a regeneration, 100% shows. As water is used, the percentage decreases until the
next regeneration. During regenerations, the percentage increases.
NOTE: Zero (%) shows until after the first regeneration begins, after connecting to electrical power.
WATER MANAGEMENT SYSTEM
FLOW RATE, GPM—
FLOW RATE
the softener (in gallons per minute). Zero shows if water is not passing through the softener.
WATER MANAGEMENT SYSTEM
GALLONS TODAY—
GALLONS TODAY
total gallons of water that have passed through the softener.
WATER MANAGEMENT SYSTEM
AVG. DAILY GALLONS—
AVG. DAILY GALLONS
household each day over the past seven day period.
NOTE: If preferred, you can set the timer to show the reading in liters instead of gallons. If GALLONS
TODAY or AVG. DAILY GALLONS exceeds 1999, a (x10) indicator appears; this means you must multiply
the number shown by ten.
ERR 02
ERR 03
• position
• motor
switch
inoperative
or wiring
harness
• timer
(PWA)
(PWA)
for the error code was not corrected.
WATER MANAGEMENT SYSTEM
%
This is the percentage of water softening capacity remaining.
CAPACITY
GPM
When using soft water, this display shows the flow rate passing through
Each day, beginning at midnight, the timer keeps a running count of the
The figure displayed is the average gallons of water used by the
ERR 04
ERR 05
• position
• timer
switch or
(PWA)
wiring
harness
• timer
(PWA)