Checking Accessories - Omron SYSDRIVE 3G3EV SERIES User Manual

Sysmac bus model compact low-noise inverter
Hide thumbs Also See for SYSDRIVE 3G3EV SERIES:
Table of Contents

Advertisement

Checking Accessories

Note that this manual is the only accessory provided with the 3G3EV (SYSMAC BUS
Model). Set screws and other necessary parts must be prepared by customers.
1-2 Precautions
To ensure safe operation of the 3G3EV, note the following items:
Always Hold the Heat Sink During Removal.
When moving the 3G3EV, always hold the heat sink (aluminum portion on the rear of the
Unit).
Watch Out for Residual Voltage On Charged Portions
After the power is turned off, residual voltage remains in the capacitor inside the
Inverter. Therefore, touching terminals immediately after turning the power off may
cause an electrical shock.
If an inspection or some other task is to be performed, always wait at least one minute
from the time all indicators on the front panel go off.
(Note that this warning is applicable whenever you perform any task after turning the
main circuit off.)
Do Not Remove the Digital Operator When the Main Circuit is
Still On.
Always turn the main circuit off before removing the digital operator.
Removing the digital operator with the main circuit ON may cause an electrical shock
and damage the equipment.
Heat sink
Chapter 1

Hide quick links: