Technical Specifications - HP ProLiant MicroServer Specifications

Hide thumbs Also See for ProLiant MicroServer:
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions (HxWxD)
(with feet)
Weight (approximate)
Input Requirements
(per power supply)
BTU Rating
Power Specifications
Power Supply Output
(per power supply)
System Inlet
Temperature
Altitude
Acoustic Noise
(Fully Loaded)
DA - 13716 Worldwide — Version 22 — December 9, 2013
10.5 x 8.3 x 10.2 in (26.7x 21.0 x 26.0 cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
http://www.hp.com/go/hppoweradvisor
Rated Steady-State Power 150 W (at 100 VAC),
Maximum Peak Power
Operating
Non-operating
Operating
Non-operating
Idle
L WAd
L pAm
HP ProLiant MicroServer
21.16 lb (9.6 kg)
13.18 lb (5.98 kg)
100 -- 127 VAC,
200 - 240 VAC
3.5 A (at 110 VAC),
2 A (at 200 VAC)
47 to 63 Hz
191.4 W (at 100 VAC),
184.9 W (at 200 VAC)
247.055 BTU/hr (at 100 VAC),
274.505 BTU/hr (at 200 VAC)
150 W (at 200 VAC)
200 W (at 100 VAC),
200 W (at 200 VAC
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 35°C (95°F).
10 to 90% relative humidity (Rh), 28°C
5 to 95% relative humidity (Rh), 38.7°C
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
3.9 BELS
22.3 dBA
Page 20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents