XP-600 Programming Instructions
®
Note: These Programming Instruction are intended to be used in conjunction with WI847C,
please refer to WI847C for additional information, instructions and definitions.
DEALER PROGRAM MODE
Hexadecimal Data Entry
To Enter a hexadecimal digit
enter the following:




A=
D=


B=
E=
C=
F=
Scroll Key
Use this key to scroll
through data that has been
entered in Programming
Entering Dealer Program Mode
N
:
OTE
Entering Dealer Program Mode is not permitted while the panel
is Armed, Reporting, or the Bell Output is on. To Enter Dealer

Mode while the Bell is ON or the panel is Reporting or Armed;
power up the panel and enter Dealer Mode within the first 3
minutes. Pressing the
key clears the 3 minute timer.
Exiting Dealer Program Mode
-
KEYPAD KEY DEFINITION

$50('

* *
5($'<

6<67(0
),5(


$&
=21( 
=21( 

  
=21( 
  
=21( 
=21( 
=21( 
!

+
Enter
Default Dealer Code shown in parentheses

Enter
N
:
OTE
After 15 minutes of keypad inactivity the keypad
will emit a steady tone indicating the panel has been
left in Dealer Program Mode. Enter Dealer Code to
exit or press the
Program mode.
Set Key
Press this key before
entering a Program-
ming Block Number.
Blank Key
Press this key to disable all fea-
tures within a LED type Program-
ming Block or to blank out digits in
a Direct Entry type Programming
Block.
Dealer Code
(4) (5) (6) (7)
Dealer Code
(4) (5) (6) (7)
D
EFAULTING THE

1. Remove power from the panel.
2. Remove all wiring from terminal
15 (PGM) and terminal 3.
key to return to Dealer
3. Connect terminal 15 (PGM) to
terminal 3.
4. Apply power to the XP-600 con-
trol panel.
5. After a few seconds the ARMED,
READY and
BLE LEDs will flash.
6. The keypad will beep 3 times
indicating the panel default val-
ues have been loaded.
7. Remove wiring between terminal
15 (PGM) and terminal 3.
8. Re-install original wiring for ter-
minal 15 (PGM) and terminal 3.
Note:
Dealer Options 1 [96] and Dealer
Options 2 [97] will not be de-
faulted. If Dealer Code Lockout
has been programmed the panel
will not default the Dealer Code.
The Event Log will be erased
when the panel is defaulted.
ARMED
ON
Indicates the panel is in Dealer
Program Mode. The panel is
READY
OFF
ready for a programming block
'
number to be entered.
SYSTEM
FLA
HING
S
ARMED
FLASHING
Indicates the panel is
Ready to exit
READY
FLAS
ING
H
Program Mode.
'
the Dealer Code to exit.
SYSTEM
FLASHING
P
ANEL
*
SYSTEM TROU-
Any
programming
in
Dealer
Enter
WI847C 8/97

Advertisement

loading

Summary of Contents for NAPCO XP-600 Express Series

  • Page 1 XP-600 Programming Instructions EFAULTING THE ANEL After 15 minutes of keypad inactivity the keypad 1. Remove power from the panel. will emit a steady tone indicating the panel has been ® 2. Remove all wiring from terminal Note: These Programming Instruction are intended to be used in conjunction with WI847C, left in Dealer Program Mode.
  • Page 2 7\SHV RI 3URJUDPPLQJ %ORFNV LED Programming Block Enable features by pressing the key that corresponds to the associated feature; the LED will turn ON. To disable a feature press the key again; the LED will turn OFF. To disable all features within a LED Type Programming Block press the key;...
  • Page 3 Blocks, data that has ZONE 1 been entered as a ‘0’ will sistance, Contact be displayed as an ‘A’: ZONE 2 the Napco Toll Subscriber ID Numbers, Phone Numbers, Pager Free Helpline ZONE 3 Leading and Trailing digits and Report Codes.
  • Page 4 =RQH )HDWXUHV Exit/Entry Zones Auto Bypass Reentry Zones Open Circuit Zones Selective Bypass Default Default Default Default Zone 1 Zone 1 Zone 1 Zone 1 See wiring Zone 2 Zone 2 Zone 2 Zone 2 diagram for Zone 3 Zone 3 Zone 3 Zone 3 Open Circuit...
  • Page 5 6\VWHP 7LPHV Exit Delay Wireless Smoke Supervisory Timer Programmable Output (PGM) Features 1 Default Smoke Supervisory Timer, hours Exit Delay, seconds Zn 1 LED ON = Audio Verification Maximum Entry 255 Maximum Entry 8 Zn 2 LED ON = *Access Output ( Zn 3 LED ON = *Follow Keypad Sounder Entry Delay Test Timer Offset...
  • Page 6 7HOHSKRQH 1XPEHU  3URJUDPPLQJ Subscriber ID Number Zone Report, Telco 1 System Reporting, Telco 1 Default Default Zone 1 Zn 1 LED ON = AC Fail Report (15 min. report delay) Zone 2 Zn 2 LED ON = Low Battery Report Zone 3 Zn 3 LED ON = *Trouble Report Telephone Number 1...
  • Page 7 %DFNXS 7HOHSKRQH 3URJUDPPLQJ 3DJHU 3URJUDPPLQJ Leading Digits Subscriber ID Number (Telco 2) Dialing Prefix Dialing Prefix for Telco 1, Telco 2 & Telco 3. Telephone Number 2 Communicator Features 1 Default Zn 1 LED ON = Communicator Enabled A fixed Dial Tone Detection (E) is included prior to the Dialing Prefix (Block Zn 2 LED ON = DTMF w/ Rotary Back up Number 44) .
  • Page 8 7HOHSKRQH 1XPEHU  3URJUDPPLQJ Subscriber ID Number Zone Report, Telco 3 System Reporting, Telco 3 Default Default Zone 1 Zn 1 LED ON = AC Fail Report (15 min. report delay) Zone 2 Zn 2 LED ON = Low Battery Report Zone 3 Zn 3 LED ON = *Trouble Report Telephone Number 3...
  • Page 9: Enhanced Communicator Features

    5HSRUW &RGHV Zone Report Codes Zone Codes Opening and Closing Code Zone 1 Alarm Code Zone 1, 2, 3, 4, 5 & 6 Restore Code The second digit of the Re- Closing Code port Code is the number of Zone 2 Alarm Code Zone 1, 2, 3, 4, 5 &...
  • Page 10 :LUHOHVV 7UDQVPLWWHUV RF ID # Point Programming Example Map point 1 of a window door transmitter, with RF ID# 0012B0:0 Zone 1 Enter the RF ID# located on to Zone 3. the Transmitter, Key Fob and Smoke Detector labels. 73 Zone 3 Zone 2 B 0 :0 Zone 3...
  • Page 11 'RZQORDGLQJ 'HDOHU 3URJUDPPLQJ Callback Telephone Number Dealer Code Dealer Options 2 Default Zn 1 LED ON = *International Dialing Protocol (4) (5) (6) (7) Zn 2 LED ON = *Invert Bell Output Zn 3 LED ON = System Trouble Auto Reset Ring Count Zn 4 LED ON = User 1 Code-Program only User 1 Code...
  • Page 12 +10 -11 +12 -13 16 VAC 20 VA FIRE FIRE BELL +PWR GND GREEN RING RING TRANSFORMER TELCO PHONE NAPCO TRF12 REMOTE BUS 2.2K (OR EQUIVALENT SEE WI850A). Class 2 Transformer. DO NOT connect to To RJ31X Zone GOLD switched...