Installing the ASM Interconnect module on the xSeries 330

The ASM Interconnect module connects the Remote Supervisor Adapter to the
ASM interconnect network. This module comes with the Remote Supervisor
Adapter option. For detailed instructions about installing the ASM Interconnect
module on servers with ASM processors and ASM PCI adapters, see the
documentation that comes with those devices.
To connect the ASM Interconnect module to the Remote Supervisor Adapter,
complete the following steps.
1. Connect the ASM Interconnect module to the ASM Interconnect port.
Note: The following illustration shows a Remote Supervisor Adapter installed
in an xSeries 330 server.
2. Connect one end of the ASM link cable (Cat 5 or 3 Ethernet cable) to the ASM
Interconnect module, and connect the other end of the link cable to the RS- 485
port.
ASM Interconnect module needed
yes
yes
yes
no
no
no
no
ASM Interconnect port
ASM link cable
on xSeries 330
RS-485 Port (A)
ASM Interconnect port
(P-P) on the Remote
Supervisor Adapter