Attention: When you handle static sensitive devices, take precautions to avoid
damage from static electricity. For details on handling these devices, refer to
"Handling static-sensitive devices" on page 138.
1. Review the information in "Before you begin" on page 48.
2. Remove the filler panel or defective hard drive from one of the hard disk drive
3. Install the new hard disk drive in the drive bay:
4. Check the hard disk drive status indicators to verify that the hard disk drives
Working with memory
The xSeries 330 supports 256 MB, 512 MB, and 1 GB 133 MHz, ECC, SDRAM,
registered x4 (Chipkill) DIMMs.
Note: Chipkill Memory protection is disabled if any DIMM in your server is not
See the ServerProven list at http://www.ibm.com/pc/compat/ for a list of
memory modules for use with the server.
84
Hardware Maintenance Manual: xSeries 330 Type 8675
bays.
a. Ensure the tray handle is open (that is, perpendicular to the drive).
b. Align the rails on the drive assembly with the guide rails in the drive bay.
c. Gently push the drive assembly into the bay until the drive connects to the
backplane.
d. Push the tray handle toward the closed position until it locks the drive in
place.
Note: The illustrations in this document might differ slightly from your
hardware.
are operating properly.
v If the amber light is on continuously, the drive has failed (only when a
ServeRAID adapter is installed.
v If the amber light flashes slowly (one flash per second), the drive is being
rebuilt (only when a ServeRAID adapter is installed).
v If the amber light flashes rapidly (three flashes per second), the controller is
identifying the drive.
an x4 DIMM.
Filler panel
Hard disk drive
Drive tray
Drive tray handle
(in open position)