Location Requirements

To ensure proper ventilation for your ice maker, the front side
must be completely unobstructed. The ice maker may be
closed-in on the top and three sides, but the installation
should allow the ice maker to be pulled forward for servicing if
necessary.
Installation of the ice maker requires a cold water supply inlet
of
" (6.35 mm) OD soft copper tubing with a shutoff valve
and either a gravity-drain system or condensate pump to
carry the water to an existing drain.
Choose a well ventilated area with temperatures above 55°F
(13°C) and below 110°F (43°C). Best results are obtained
between 70°F (21°C) and 90°F (32°C).
The ice maker must be installed in an area sheltered from the
elements, such as wind, rain, water spray, or drip.
When installing the ice maker under a counter, follow the
recommended opening dimensions shown. Place electrical
and plumbing fixtures in the recommended location as shown.
NOTES:
Be sure the power supply cord is not pinched between the
ice maker and the cabinet.
Be sure the water supply line is not pinched between the
ice maker and the cabinet.
Be sure the drain line (on some models) is not pinched
between the ice maker and the cabinet.
34"
(86.4 cm)
Min.
34 "
(87.6 cm)
3 "
Max.
(8.9 cm)
24"
(60.1 cm)
A. Recommended location for electrical
and plumbing fixtures
B. Floor level
Choose a location where the floor is even. It is important for
the ice maker to be level in order to work properly. If needed,
you can adjust the height of the ice maker by changing the
height of the leveling legs. See "Leveling."
4
11 "
(29.2 cm)
28 "
(72.4 cm)
9"
(22.9 cm)
15"
(38.1 cm)

Electrical Requirements

Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Before you move your ice maker into its final location, it is
important to make sure you have the proper electrical connection:
A 115 volt, 60 Hz., AC only, 15- or 20-amp electrical supply,
properly grounded in accordance with the National Electrical
Code and local codes and ordinances, is required.
It is recommended that a separate circuit, serving only your ice
maker, be provided. Use a receptacle which cannot be turned off
by a switch or pull chain.
IMPORTANT: If this product is connected to a GFCI (Ground Fault
Circuit Interrupter) equipped outlet, nuisance tripping of the power
supply may occur, resulting in loss of cooling. Ice quality may be
affected. If nuisance tripping has occurred, and if the condition of
the ice appears poor, dispose of it.
Recommended grounding method
A
The ice maker must be grounded. The ice maker is equipped with
a power supply cord having a 3 prong grounding plug. The cord
must be plugged into a mating, 3 prong, grounding-type wall
receptacle, grounded in accordance with the National Electrical
Code and local codes and ordinances. If a mating wall receptacle
is not available, it is the personal responsibility of the customer to
have a properly grounded, 3 prong wall receptacle installed by a
qualified electrician.
B

Water Supply Requirements

A cold water supply with water pressure of between 30 and
120 psi (207 and 827 kPa) is required to operate the ice maker. If
you have questions about your water pressure, call a licensed,
qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT:
Reverse osmosis water filtration systems can be used only
with ice maker installations that have a gravity drain. A reverse
osmosis system is not recommended for ice makers that have
a drain pump installed.
The pressure of the water supply coming out of a reverse
osmosis system going to the water inlet valve of the ice maker
needs to be between 30 and 120 psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).