Maintenance - HP Surestore Tape Library Model 10/180 Manual

Web-based library administrator help
Hide thumbs Also See for Surestore Tape Library Model 10/180:

Advertisement

Diagnostics
Diagnostics allows you to clean a drive, as well as test the functionality of the following:
é
Robotic hand assembly using Get-Put loops
é
Drives through practice mounts and dismounts
é
Robot by testing in a Demo mode
To display the Diagnostics screen:
é
Select Maintenance->Diagnostics
To cancel an operation:
1.
Click Stop.
2.
Enter your library password and click OK.
Note: You can have this field automatically populated with the password by clicking remember
password.
To clean a drive:
1.
Click Clean Drive.
2.
Select the drive to clean and click in the Drive ID field.
3.
Select the Drive ID.
4.
Click Start.
5.
Enter your library password and click OK.
Note: You can have this field automatically populated with the password by clicking remember
password.
The drive is cleaned at the next available cycle.
To test the function of the robotic hand assembly:
1.
Click Get/Put.
2.
Set the loop count.
This allows you to track Gets and Puts. A warning message is displayed informing you that the
library is unavailable for host operations. Any backups in progress, fail.
3.
Click Start.
4.
Enter your library password and click OK.
Note: You can have this field automatically populated with the password by clicking remember
password.
To test the drive where the diagnostic cartridge is mounted or dismounted from the selected drive:
1.
Click Mount or Dismount.
2.
Enter a specific tape drive where the cartridge is to be mounted or dismounted.
3.
Click Start.
4.
Enter your library password and click OK.
Note: You can have this field automatically populated with the password by clicking remember
password.

Maintenance