Log Options Tab; Standby Onboard Administrator Screen - HP Integrity Superdome 2 16-socket User Manual

Administrator user guide
Hide thumbs Also See for Integrity Superdome 2 16-socket:
Table of Contents

Advertisement

Enclosure Event 0x1204: Flash Complete
Enclosure Event 0x1210: Non-iLo EBIPA

Log Options tab

This screen enables you to send system log messages to a remote host. By default, the local system
log is enabled. To manage the system log settings, you must be an Administrator or Operator with
OA bay permissions.
To send system log messages to a remote host, select the Enable remote system logging check box.
Box
Syslog Server Address
Port
To send a test message to the remote host address and to the local system log, click Test Remote
Log. You must enable remote system logging to use this function.
To save the settings, click Apply.

Standby Onboard Administrator screen

When a second HP Superdome 2 Onboard Administrator is placed in the enclosure, it becomes
the standby Onboard Administrator. The standby Onboard Administrator is normally placed in
the available Onboard Administrator tray at the rear of the enclosure. By selecting the Active to
Standby screen, you can force a transition within the Onboard Administrator user interface to make
the active Onboard Administrator become the standby Onboard Administrator.
For an Active or Standby relationship, the two Onboard Administrator modules must have the same
firmware version installed. If the firmware versions are not identical, the Insight Display and the
main status screen of the Onboard Administrator identifies this error and alerts the user through
SNMP if enabled.
If using two Onboard Administrators, each Onboard Administrator has a unique IP address. Refer
to the Insight Display to get the IP addresses for the Active and Standby Onboard Administrators
Possible value
###.###.###.###. where ###
ranges from 0 to 255
An integer between 1 and 65535
Description
The IP address of the remote host
The IP port of the remote host. If this box
is left blank, the default UDP port 514
is used.
Onboard Administrator Module 109

Advertisement

Table of Contents
loading