Identifying Problems; Example Alert For A Failed Disk; Using The Storeonce Gui To Identify A Failed Disk; Viewing The Events Log - HP StoreOnce 4700 Service And Maintenance Manual

Table of Contents

Advertisement

Identifying problems

Example alert for a failed disk

It is possible to configure recipients for SNMP traps or email alerts, as described in the HPE StoreOnce
Backup User Guide for your product. These users will be notified of any problems with hardware
components. You can also use the StoreOnce GUI and StoreOnce CLI, as described below, to identify
problems and access alerts.
The following examples illustrate how problems with a hard disk can be identified.
The following event occurred: hardwarecomponent.failure
Severity:
Event code:
Date:
Appliance:
System URL(s):
component:drive, status:FAILED, location:drive S/N:5C7229P34B in bay 11 in
Drawer 2 of driveEnclosure S/N:CZ7229P340:, Message: The drive is not ready
and will not spin up., Diagnostic message: Reseat the drive. If reseating
the drive does not resolve the issue, replace the drive.,
uuid:Drive_Missing_b1000085, eventId:00030002, level:ALERT,
category:STORAGE_CLUSTER, overallStatus:DEGRADED, name:
vs_02358fe6-0000-1000-b012-53344230334b

Using the StoreOnce GUI to identify a failed disk

Viewing the Events Log

Select Events. The alert is recorded in the Events window with Event Details at the bottom of the window.
20
Identifying problems
ALERT
Ennnnnnnn
Wed Jan 21 14:19:21 UTC 2013
HPCZ225101H9
http://<IP_address1>, http://<IP_address2>

Advertisement

Table of Contents
loading

Table of Contents