5. Go to the location of the first artifact (as shown in the src value under the file tag).
6. Copy the artifact from the extracted folder to the source folder in the
7.
8. Go to the Install_Home/conf directory.
9. Open the version.properties file in a text editor.
10. Change the patch version (patch.version) value to the reverted patch (for example, if you are
11. Go to the Install_Home/patch-backup/conf directory.
12. Copy the patch.conf file in this directory to the Install_Home/conf directory.
13. Start all services by completing the following steps.
DCFM Professional Plus User Manual
53-1001774-01
Install_Home/patch-backup directory.
Repeat step 5 and 6 for all artifacts listed in the restore.xml folder.
reverting from patch F to patch C then
If the previous version is the initial version (no patches), change the patch version value to
none (for example,
patch.version = None
If the previous version is the initial version (no patches), delete the patch.conf file in the
Install_Home/conf directory.
a. Launch the Server Console.
b. Click the Services tab.
c.
Click Start to start all services.
).
patch.version = c
).