BenQ MS504 User Manual page 49

User manual for ms504 and mx505
Hide thumbs Also See for MS504:
Table of Contents

Advertisement

Indicators
Light
Orange
Green
Flashing
Green
Orange
Flashing
Red
Green
Red Flashing
Off
Off
Green
Red
Red
Flashing
Green
Power events
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Red
Off
Off
Lamp events
Off
Red
Orange
Off
Flashing
Off
Red
Thermal events
Red
Off
Red
Off
Red
Off
Status & Description
Stand-by mode
Powering up
Normal operation
Normal power-down cooling
Download
CW start fail
Scaler shutdown fail (data abort)
Lamp1 error in normal operation
Lamp is not lit up
Lamp usage time exceeded
Fan 1 error (the actual fan speed is +25% outside
the desired speed)
Fan 2 error (the actual fan speed is +25% outside
the desired speed)
Temperature 1 error (over limited temperature)
Maintenance
49