Installing the Stove
Continue
adding
components, locking each
succeeding component into
place.
3. Install Support Brackets
For Horizontal Runs - The vent system must be
supported every 5 feet (150cm) of horizontal run by
a horizontal pipe support.
To install support brackets for
horizontal runs:
• Place the pipe supports
around the vent pipe.
• Nail the pipe supports to
the framing members.
For Vertical Runs - The vent
system must be supported
every 8 feet (240cm) above
the stove vent outlet by wall
brackets.
To install support brackets for
vertical runs:
• Attach wall brackets to
the vent pipe and secure
the wall bracket to the fram-
ing members with nails or
screws.
(continued)
vent
Figure 12. Adding
Venting Components
1 INCH MIN.
(25.4mm)
Figure 13. Installing
Support Brackets
Installation
Figure 12.
Ajout de sections
3. Pose des supports de montage
Sections horizontales - Le système de ventilation
doit être soutenu par un support horizontal tous les
150cm (5 ft) de conduit horizontal.
WALL
BRACKET
(SUPPORT
MURAL)
WALL STUD
(MONT ANT DU MUR)
(240cm)
VENT OUTLET
(ORIFICE
D'ÉCHAPPEMENT)
Figure 13.
Pose des supports de montage
22
(suite)
Continuer à ajouter des
sections et à les verrouiller
successivement
Pour poser des supports de
conduit horizontal:
• Placer les supports autour
du conduit.
• Clouer les supports dans
les montants de la char-
pente.
Sections verticales - Le
système de ventilation doit
être soutenu par des supports
accrochés aux murs tous les
240cm (8 ft) au-dessus de
l'orifice d'échappement de
l'appareil de chauffage.
8 ft
Pour poser les supports de
conduit vertical:
• Attacher les supports
muraux sur le conduit et
les clouer ou visser sur
les montants de la char-
pente.