Installing the Stove

VENTING WITH ONE (1) 90
(VENTILATION AVEC UN (1) COUDE À 90
V
2'MIN.(610mm)
3'MIN.(914mm)
4'MIN.(120cm)
18' MIN.(540cm)
NOTE: Optional Kit #970D can be
used for this type of installation on
model Tiara I.
REMARQUE: Le kit n
peut être utilisé pour ce type
d'installation du modèle Tiara I.
Figure 8. Vent System with One
(continued)
Tiara I
ELBOW
0
H
2'MAX.(610mm)
3'MAX.(914mm)
4'MAX.(120cm)
18' MAX.(540cm)
V + H = 40' MAX.(1200cm)
H = 18' MAX.(540cm)
970D en option
o
90° Elbow
Installation
VENTING WITH ONE (1) 90
(VENTILATION AVEC UN (1) COUDE À 90
0
)
V
2'MIN.(610mm)
3'MIN.(914mm)
4'MIN.(120cm)
18' MIN.(540cm)
V + H = 40' MAX.(1200cm)
H
Figure 8. Système de ventilation
17
(suite)
Tiara II
0
ELBOW
)
0
H
2'MAX.(610mm)
3'MAX.(914mm)
4'MAX.(120cm)
15' MAX.(450cm)
H = 15' MAX.(450cm)