Installing the Stove
Minimum Clearances
from the Stove to Combustible Materials
Glass Front
Floor
Rear
(Tiara I)
(Tiara II)
Sides
(Tiara I)
(Tiara II)
Floor to Ceiling
Minimum Clearances from the
Vent Pipe to Combustible Materials
For Horizontal Sections:
For Vertical Sections:
At Wall Firestops:
For minimum clearances, see the direct vent
termination clearance diagrams on page 27 thru 29
in this manual.
(continued)
Inches
36
0
4
6
6
9
72
Top
3 inches
Bottom
1 inch
Sides
1 inch
1 inch
Top
2 1/2 inches
Bottom
1/2 inch
Sides
1 inch
Installation
(suite)
Distance minimum entre de ventilation de chauffage
et les matériaux combustibles
m m
914
Vitre Avant
0
Plancher
102
Arrière (Tiara I)
152
152
Côtés de l'appareil (Tiara I)
229
1830
Plancher au plafond
Distances minimum entre le conduit
de ventilation et les matériaux combustibles
Sections horizontales:
Sections verticales:
Coupe-feu mural:
Pour les distances d'isolation minimum, voir les
schémas de mitres de ventilation directe, page 27
et 29 de ce guide.
11
(Tiara II)
(Tiara II)
Haut
75mm
Bas
25mm
Côtés
25mm
25mm
Haut
63,7mm
Bas
13mm
Côtés
25mm