1. Float Switch
See "II.D. Float Switch Check
and Cleaning."
2. Inlet Water Valve
3. Water Supply
4. Water Control Relay
5. Time Delay Relay
1. Bin Control Thermostat Assembly
(with integrated heater)
Refill
a) Dirty/sticking.
b) Defective.
a) Screen or orifice clogged.
b) Defective.
a) Water supply off or improper water pressure (7 to 113 PSIG).
b) External water filters clogged.
a) Defective.
a) Defective.
Shutdown
a) Open with bin filled with ice.
b) Out of position.
c) Out of adjustment. See "II.C. Bin Control Check."
d) Bad contacts.
e) Bad thermostat heater.
19