Bright Adjustment (Dd-123 Board); Contrast Adjustment (Dd-123 Board) - Sony DCR-TRV8 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-TRV8:
Table of Contents

Advertisement

2. Bright Adjustment (DD-123 board)

Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Camera
Subject
Arbitrary
Pin 4 of CN2904 (EVF VG) on
Measurement Point
VC-217 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
7A
Specified Value
A = 7.25 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 22, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: D, address: 7A, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
(The data of address: 7A should be "54" to "D7".)
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 22, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
2H
Pedestal
Fig. 5-1-15.
Pedestal
A

3. Contrast Adjustment (DD-123 board)

Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 22, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: D, address: 7B, change the data and set the voltage
(A) between the 100 IRE and 0 IRE (pedestal) to the specified
value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 22, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
100 IRE
A
0 IRE (Pedestal)
5-29
Camera
Arbitrary
Pin 4 of CN2904 (EVF VG) on
VC-217 board
Oscilloscope
D
7B
A = 1.81 ± 0.05V
2H
Fig. 5-1-16.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents