3Com 4210G Series Configuration Manual page 1104

24-port/48-port
Hide thumbs Also See for 4210G Series:
Table of Contents

Advertisement

Interface name
For a device operating independently (that is, the device does not belong to any IRF), its interface
name is in the following format: member ID/slot number/interface serial number, where
By default, member ID is 1.
After a device leaves an IRF, it continues using the member ID when it was in the IRF as its
device ID.
Subslot number is the number of the slot in which the LPU resides. For a box-type device, LPUs
are fixed on the device, so the slot number is a fixed value. On the Switch 4210G series, the
subslot on the front panel is numbered 0, and subslots of the two expansion slots on the rear
panel are numbered 1 and 2 from left to right.
Interface serial number is dependent on the number of interfaces supported by the device. View
the silkscreen on the interface card for the number of supported interfaces.
For example, GigabitEthernet 1/0/1 is an interface on the independently operating device Sysname.
To set the link type of GigabitEthernet 1/0/1 to trunk, perform the following steps:
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] port link-type trunk
For an IRF member, the interface name also adopts the previously introduced format: member ID/slot
number/interface serial number, where
The member ID identifies the IRF member on which the interface resides
Meaning and value of the subslot number and the interface serial number are the same as those
on an independently operating device.
For example, GigabitEthernet 1/0/1 is an interface on IRF member slave 3 (member ID is 3). To set the
link type of GigabitEthernet 1/0/1 to trunk, perform the following steps:
<Master> system-view
[Master] interface gigabitethernet 3/0/1
[Master-GigabitEthernet3/0/1] port link-type trunk
File system name
You can use the name of the storage device to access the file system of an independently operating
device. For the naming rules of a storage device, refer to the File System Management Configuration
in the System Volume.
For example, flash is the storage device on the independently operating device Sysname. To back up
the file aa.cfg under the root directory of the flash to the test folder, perform the following steps:
<Sysname> mkdir test
...
%Created dir flash:/test.
<Sysname>copy aa.cfg test/aa(20080714).cfg
Copy flash:/aa.cfg to flash:/test/aa(20080714).cfg?[Y/N]:y
..
%Copy file flash:/aa.cfg to flash:/test/aa(20080714).cfg...Done.
<Sysname> cd test
<Sysname> dir
Directory of flash:/test/
26-9