Door Profile - Bosch D9210C Program Entry Manual

Access control interface module
Table of Contents

Advertisement

Access Control Interface Module
2

Door Profile

This programming category is used to:
Door #
Default:
Selections
Enter the number of the door you are about to program.
NOTICE!
The D9412 Family supports 8 doors; the D7412 Family supports 2 doors.
D# Entry Area #
Default:
Selections:
Assign an area to the door controller. This entry allows the D9210C to be polled activating
communication to the panel. This also is the area a user will exit when initiating a Request to
Exit [REX].
1-8 The area assigned to the door controller to which the reader will allow access.
Blank Door controller will not function.
NOTICE!
All SDI devices, regardless of area assigned, will report to Area 1, Account 1 by default upon
SDI failure. If an interface module becomes disconnected, SDI Fail ## and MISSING POINT ###
events will be created.
NOTICE!
9210 NOT READY will appear at this command center when you press the [ENTER] key if the
interface module is not programmed with a D# Entry Area.
D# CC# Scope
Default:
Selections:
Enter the Command Center number [CC#] which determines the scope of the user ID's
disarming rights. Areas will disarm on the basis of this Command Center's scope and the
Authority Level of the user.
Bosch Security Systems, Inc.
Assign an area which also activates the interface module.
Assign a point to the door.
Program the door state to change when the arm state changes.
Allow for the strike relay to activate upon a fire alarm.
1
1-8
Blank
Blank, 1-8
Blank
Blank, 1-8