NOTE:
If compressor lockout is set to ON, the thermostat will not call for cool
until after the 5 minute safety time period and will display the message A/C
return < 5 min. After the 5 minutes expire the thermostat will call for cool.
3.
If the system is a multi-stage cooling system, adjust the
temperature setting to at least 3° below room temperature.
The second stage cooling should begin to operate.
4.
Press the
temperature. The cooling system should stop operating.
Check the heating system
1.
Press Heating / Cooling Mode key one or more times to select
HEAT mode. If the auxiliary heating system has a standing pilot,
be sure to light it.
2.
Press the
temperature. The heating system should begin to operate.
NOTE: If the system is configured as a heat pump and compressor lockout is
set to ON, the thermostat will not call for heat until after the 5 minute safety
time period. After the 5 minutes expire the thermostat will call for heat.
3.
If the system is a multi-stage heating system, adjust the
temperature setting to at least 3° above room temperature. If the
system is configured for a multi-stage furnace (non-heat pump),
the second stage of the heating should begin to operate. Within a
very short period, the Back Up heat should begin to run and Back
Up Heat will be displayed.
4.
Press the
The heating system should stop operating.
to adjust the temperature setting above room
to adjust thermostat setting to 1° above room
to adjust the thermostat below room temperature.