If the system is a single or multi-stage conventional
system, your options are:
Outdoor Options:
Air Conditioner: 1 Stage (default)
Air Conditioner: 2 Stage
Air Source Heat Pump: 1 Stage
Air Source Heat Pump: 2 Stage
Geothermal Heat Pump: 1 Stage
Geothermal Heat Pump: 2 Stage
None
NOTE: The presence of a wire in the W2 terminal is a good indication
that the user has two-stage equipment located inside the house
(furnace, air handler, or boiler). The presence of a wire in the Y2
terminal is a good indication that the homeowner has two-stage
equipment located outside the house (air conditioner or heat pump).
2. Network Settings
Installation > Network Settings > Installation Information
This menu item provides you with the MAC ID and ZigBee Installation
Code that will be requested from you when you pair this device to a
ZigBee network.
Installation > Network Settings > Network Connection
This menu option enables you to
send a join request to the ZigBee
network. For more information on
this process, see step 5 (page 18).
10
Indoor Options:
Air Handler: No Heat
Air Handler: Electric Heat – 1 Stage
Air Handler: Electric Heat – 2 Stage
Furnace Gas / Oil – 1 Stage (default)
Furnace Gas / Oil – 2 Stage
Boiler: 1 Stage
Boiler: 2 Stage
Installation Information
Settings
Installation Code
XXXX-XXXX
MAC Address
XXXX-XXXX-XXXX-XXXX