Product Specifications - Fluke 566 Technical Data

Fluke 566 and 568 thermometers specifications
Hide thumbs Also See for 566:

Advertisement

Product specifications

Infrared temperature range
Infrared accuracy
Display resolution
Infrared spectral response
Infrared response time
Thermocouple Type-K
input temperature range
Thermocouple Type-K
input accuracy
D:S (distance to measurement
spot size)
Laser sighting
Minimum spot size
Emissivity adjustment
Data storage with Date/Time stamp
PC Interface and cable
Hi/Low alarms
Min/Max/Avg/Dif
Display
Backlight
Trigger lock
Switchable Celsius and Fahrenheit
Power
Battery life
Operating temperature
Storage temperature
Bead thermocouple Type-K range
Bead thermocouple Type-K accuracy
Ordering information
Fluke-566 Infrared thermometer
Fluke-568 Infrared thermometer
Includes: Infrared thermometer with con-
tact thermometer capabilities, FlukeView
Forms software (568 only), USB cable (568
only), K-type thermocouple bead probe, hard
carrying case, quick start guide, and users
manual.
566
-40 °C to 650 °C (-40 °F to 1202 °F)
< 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
> 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater
-270 °C to 1372 °C (-454 °F to 2501 °F)
-270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F))
-40 °C to 1372 °C: ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater
30:1
Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
20 points
None
Dot matrix 98 x 96 pixels with function menus
Two levels, normal and extra bright for darker environments
2 AA/LR6 Batteries
If used continuously: laser and backlight on,12 hours; laser and backlight off, 100 hours
0 °C to 50 °C (32 °F to 122 °F)
-20 °C to 60 °C (-40 °F to 140 °F)
-40 °C to 260 °C (-40 °F to 500 °F)
± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F)
from -40 °C to 0 °C (-40 °F to 32 °F)
®
-40 °C to 800 °C (-40 °F to 1472 °F)
0.1 °C / 0.1 °F
8 µm to 14 µm
< 500 msec
19 mm (0.75 in)
USB 2.0 with FlukeView® Forms software
Audible and two-color visual
Yes
Yes
Yes
2 AA/LR6 Batteries and USB when used with a PC
Fluke. Keeping your world
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2007 Fluke Corporation. All rights reserved.
Specifications subject to change without notice.
Printed in U.S.A. 8/2007 3085001 D-EN-N Rev A
568
50:1
99 points
up and running.
®

Advertisement

loading

This manual is also suitable for:

568