Advertisement
The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target's surface. Note that the Japanese models indicate Celsius only.
Read all safety information before you use the Product.
A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test.
Table 1 tells you about symbols used on the Product and in this manual.
To prevent eye damage and personal injury:
Table 1. Symbols
Symbol | Meaning | Symbol | Meaning |
Risk of danger. Important information. See Manual. | Do not dispose of this product as unsorted municipal waste. Go to Fluke's website for recycling information. | ||
Warning. Laser. | Conforms to European Union directives. | ||
Battery | Conforms to relevant Australian standards. |
To avoid damage to the Product, do not leave the thermometer on or near objects of high temperature.
To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure above.
Use soap and water on a damp sponge or soft cloth to clean the Product case. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water.
62 MAX | 62 MAX + | |
Temperature Range | -30°C to 500°C (-22°F to 932°F) | -30°C to 650°C (-22°F to 1202°F) |
Accuracy | ≥0°C: ±1.5°C or ±1.5% of reading, whichever is greater (≥32°F: ±3°F or ±1.5% of reading, whichever is greater) ≥ -10°C to <0°C: ±2°C (≥14°F to <32°F: ±4°F) < -10°C: ±3°C (<14°F: ±6°F) | ≥0°C: ±1°C or ±1% of reading, whichever is greater (≥32°F: ±2°F or ±1% of reading, whichever is greater) ≥ -10°C to <0°C: ±2°C (≥14°F to <32°F: ±4°F) < -10°C: ±3°C (<14°F: ±6°F) |
Response Time (95%) | <500 ms (95% of reading) | <300 ms (95% of reading) |
Spectral Response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical Resolution | 10:1 (calculated at 90% energy) | 12:1 (calculated at 90% energy) |
Display Resolution | 0.1°C (0.2°F) | |
Repeatability (% of reading) | ±0.8% of reading or ±1.0°C (2°F), whichever is greater | ±0.5% of reading or ±0.5°C (1°F), whichever is greater |
Power | 1 AA IEC LR06 Battery | |
Battery Life | 10 hours with laser and backlight on | 8 hours with laser and backlight on |
Weight | 255 g (8.99 oz) | |
Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches | |
Operating Temperature | 0°C to 50°C (32°F to 122°F) | |
Storage Temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
Operating Humidity | 10% to 90% RH non-condensing @ 30°C (86°F) | |
Operating Altitude | 2000 meters above mean sea level | |
Storage Altitude | 12,000 meters above mean sea level | |
IP Rating | IP 54 per IEC 60529 | |
Drop Test | 3 meters | |
Vibration and Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 |
Compliance - EN/IEC 61010-1: 2001
Laser Safety - FDA and EN 60825-1 Class II
This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
To contact Fluke, call one of the following telephone numbers:
Or, visit Fluke's website at www.fluke.com.
To register your product, visit http://register.fluke.com.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the 62 MAX that isn't answered in the manual? Leave your question here.