234
IBM Tivoli Monitoring: Troubleshooting Guide
Table 19. Resolving problems sending events to Netcool/OMNIbus (continued)
Cause
Configuration of the EIF
destination is incorrect.
Resolution
Review the configuration of the OMNIbus EIF destination on
the IBM Tivoli Monitoring side. Verify that the server and port
information are correct. You can use the IBM Tivoli Monitoring
CLI command listeventdest to list all the event destinations
and use IBM Tivoli Monitoring CLI command vieweventdest to
see detail of the event destination. If you have defined more
than one event destination, make sure you are looking at the
correct one. For example:
tacmd listeventdest
Server Id Server Name
0
Default EIF Receiver TEC
1
nswin01-OM
tacmd vieweventdest -i 0
Server Id : 0
Server Name: Default EIF Receiver
Server Type: TEC
Description: default EIF event listener
Default
: Y
Host1
: nswin02:5527
tacmd vieweventdest -i 1
Server Id : 1
Server Name: nswin01-OM
Server Type: Micromuse/Omnibus
Description: Windows OMNIbus Server
Default
: N
Host1
: nswin01:9998
Server Type
Micromuse/Omnibus

Advertisement