'DATA SET NOT FOUND' JCL error occurs when submitting the
DS#3xxxx monitoring server create runtime members job.
If you get a DATA SET NOT FOUND error when you attempt to create runtime
members on your z/OS Tivoli Enterprise Monitoring Server, check that the RTE
build job was successful and that the fields were set correctly.
Ensure the following:
v The pp#1xxxx RTE Build job successfully ran for this RTE. To perform the RTE
Build job,
1. Place the B option next to the RTE on the KCIPRTE RTE main menu to
instruct Configuration tool generates the pp#1xxxx mRTE Build job.
2. Ensure that the RTE Build job contains allocations for the
&rvhilev.&rte.RKDS* and &rvhilev.&rte.RK* runtime libraries.
3. Submit the RTE Build job.
v The Tivoli Enterprise Monitoring Server in this RTE field is set to Y on the
RTE Update panel if the RTE Build job does not contain &rvhilev.&rte.RKDS*
libraries. If you must edit the field, regenerate the RTE Build job.
For more information about configuring a z/OSTivoli Enterprise Monitoring Server
and the RTE Build job. see the Configuring the Tivoli Enterprise Monitoring Server on
z/OS (http://publib.boulder.ibm.com/infocenter/tivihelp/v15r1/topic/
com.ibm.itm.doc_6.2.3fp1/itm623fp1_zconfigtems.htm).
The error 'CMSLIST NOT ALLOWED' occurs on the 'Specify
Advanced Configuration Values' panel when Tivoli Enterprise
Monitoring Server type equals hub.
The F10=CMSLIST key from the Specify Advanced Configuration Values panel is
only applicable to a remote Tivoli Enterprise Monitoring Server. This PF Key
allows the remote Tivoli Enterprise Monitoring Server to select a hub Tivoli
Enterprise Monitoring Server to which it can connect. The F10=CMSLIST function
key is unavailable to a hub Tivoli Enterprise Monitoring Server. Go to the previous
Specify Configuration Values panel to verify what type of Tivoli Enterprise
Monitoring Server you are configuring
The 'Enter required field' error occurs for the 'Global location
broker applid of Hub' or the 'Network ID of Hub' VTAM-related
fields
About this task
On the Specify Configuration - Hub Values for Remote Tivoli Enterprise
Monitoring Server panel, the message "Enter required field" occurs although the
remote z/OS Tivoli Enterprise Monitoring Server connects to the Hub Tivoli
Enterprise Monitoring Server through IP protocols. If you are configuring a remote
z/OS-based Tivoli Enterprise Monitoring Server that connects to a non-z/OS Hub
Tivoli Enterprise Monitoring Server via the IP or IPPIPE communication protocol,
use the following steps as a resolution:
1. On the Specify Configuration - Hub Values for Remote Tivoli Enterprise
Monitoring Server panel, enter any value in the following fields:
v Global location broker applid of Hub. For example, enter default
"CTDDSLB" if this VTAM APPLID is not used.
v Network ID of Hub. For example, enter the NETID value from
SYS1.VTAMLST(ATCSTRnn)).
Chapter 5. Installation and configuration troubleshooting