Door Gasket; Glass Cleaning; Door Removal; Glass Replacement - Regency Alterra CI1200 Owners & Installation Manual

Wood inserts
Table of Contents

Advertisement

MAINTENANCE

DOOR GASKET

If the door gasket requires replacement, 7/8" diameter material must be used.
A proper high temperature gasket adhesive is required. A gasket repair kit,
Part # 846-570 is available from your local Regency dealer.

GLASS CLEANING

Only clean your glass window when it is cool. Your local retailer can supply
you with special glass cleaner if plain water and a soft cloth does not remove
all deposits.

DOOR REMOVAL

When handling cast parts, please handle with care as they can be damaged.
1) Open door to a 45° angle
2) Holding door fi rmly from top and bottom - lift door up and off to remove.
Note: Door is heavy.
DOOR INSTALLATION NOTE
After re-installing the door, care-
fully swing open and check the
clearance to the Right Hand Cast
Side. If tight or rubbing, loosen the
7/16 nuts and adjust the clearance
and then re-tighten.
24

GLASS REPLACEMENT

Allow the stove to cool before removing or replacing glass. Remove the door
from the stove and remove the glass retainer. Use caution when removing
broken glass to avoid injury. When placing the replacement glass in the door,
make sure that the glass gasketing will properly seal your unit. Replace the
retainer, it should rest on the gasket not the glass, and tighten securely with a
glass clips and screws. Do not wrench down on the glass as this may cause
breakage.
Your Regency Insert is supplied with 5mm Neoceram ceramic glass that will
withstand the highest heat that your unit will produce. In the event that you
break your glass by impact- purchase replacement glass (940-366/P) from an
authorized Regency dealer only. Follow the instructions to replace.
Lower glass clip
Glass clip screw locations
Avoid impact on glass doors such
as striking or slamming shut.
Regency CI1200 / CI1250 Wood Cast Insert