TROUBLESHOOTING
Try the solutions
suggested
here first in order to avoid the cost
of an unnecessary
service
call.
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
PROBLEM
RECOMMENDED
SOLUTIONS
Ice Maker Will Not
Check that it is plugged into a grounded 3 prong outlet.
Operate
Check that the control is turned on. See "Using the Controls."
Replace the fuse or reset the circuit breaker.
NOTE: If problems continue, contact an electrician.
Room temperature must be above 55°F (13°C). Otherwise, bin thermostat may sense cold room
temperature
and shut off even though the bin is not full of ice. The ice maker may not restart once it
does shut off.
If there was a large amount of water added to the ice maker, wait a few minutes for the drain pump to
clear. If there is still water in the bin, check to see whether the drain hose is kinked.
For models with drain pumps, check that the drain hose is not damaged, or kinked or pinched
between cabinet and ice maker. Use only Whirlpool approved drain pump kit, Part #1901A.
Ice Maker
Seems
Noisy
Is the water in the reservoir overflowing? This is normal. This overflow helps to purge minerals that
were removed from the water during the ice making process.
Is there a "whooshing"
sound? Check the following things:
Check that the water supply is hooked up and turned on.
Check that the drain cap is tight and the water drain pan pump is securely attached to the water
pan.
Is there ice between
the evaporator
plate and the cutting
grid? Check that the ice maker is level.
See "Leveling." If the ice maker is level, and the problem persists, run a cleaning cycle. See
"Cleaning."
If the ice maker is connected to a water supply pressure in excess of 60 psi, you may hear a loud
sound during water filling associated with the flow of water through the inlet valve. Call a licensed,
qualified plumber to determine the best method to reduce the supply water pressure (50 psi is
recommended).