Panel Test - Furuno CSH-5 MARK-2 Operator's Manual

Color scanning sonar
Hide thumbs Also See for CSH-5 MARK-2:
Table of Contents

Advertisement

Conti Test
This is a continuous test of the Display and Transceiver Units. Addi-
tionally checked devices are DROM and DRAM.
CONTI TEST
MAIN 105-0541-XXX 105-0542-XXX
ROM
= OK
RAM
= OK
P.W
= OK
DROM
= OK
DRAM
= OK
DPRAM
= OK
TRX
105-
-XXX 105-
ROM
= OK
RAM
= OK
DROM
= OK
I/F
105-0267-XXX
ROM
= OK
RAM
= OK
DPRAM
= OK
GYRO
= OK
LOG
= OK
PRESS [MENU] 2 or 3 SECONDS TO STOP SELFCHECK

Panel Test

This test checks the controls on the front panel and the control box
for proper operation.
PANEL TEST
0 0
0 0
0 0 0 0 0 0
0 0 X = 0 0
7
3 0 0 Y = 0
0 0
PRESS [MENU] 2 or 3 SECONDS TO STOP SELFCHECK
SIO Test
This test checks the input/output parts of the Transceiver Unit. The
results of the test are indicated as OK or NG.
SIO TEST
MAIN SIO1 = OK
SIO2 = OK
I/F
SIO-NAV = NG
SIO-CI
= NG
PRESS [MENU] 2 or 3 SECONDS TO STOP SELFCHECK
55
0635 e 107kHz
-XXX
0644 e 85kHz
Not displayed if interface module
CSH-5060 is not provided.
Main Panel
Press each control one by one.
The figure should change if the
control is functioning properly.
Control Box
Repeat the above procedure.
SIO1: Checks communication line
between display and
transceiver unit.
SIO2, SIO-NAV and SIO-CI check
communication line between interface
module (option) and display unit.
Short-plug is required to conduct this
test.

Advertisement

Table of Contents
loading

Table of Contents