Carrier aquazone 50RTG Installation, Start-Up And Service Instructions Manual page 8

Rooftop water source heat pump units
Table of Contents

Advertisement

50RTG03-07 WITH ECONOMIZER AND COMPLETE C CONTROLLER
Ground
L1
Power Supply
L2
Refer to Data Plate
Use copper conductors only.
L3
RED
(208V)
SEE
VIO or
NOTE 7
BLK/RED
(460V)
BLU
GRY
or
BLK
SEE
BLU
NOTE 3
24V
C
ORG
CB
230V
YEL
R
Y
P1
Compressor
Y
Y
W
Cooling
O
O
Fan
G
G
24 VAC
R
R
Common
C
C
Alarm
L
AL1
AL2
Typical T-stat
Alarm
SEE NOTE 5
A
Relay
AL
Alarm Relay Contacts
BC
Blower Mtr Contactor
CB
Circuit Breaker
CC
Compressor Contactor
ECR —
Economizer Relay
EH1 —
Auxiliary Heat Stage 1
EH2 —
Auxiliary Heat Stage 2
ES
Enthalpy Sensor
FP1
Sensor, Water Coil Freeze Protection
FP2
Sensor, Air Coil Freeze Protection
HP
High Pressure Switch
JW1 —
Jumper, Alarm Mode
LAR —
Low Ambient Relay
LOC —
Loss-of-Charge Pressure Switch
MAS —
Mixed Air Sensor
NEC —
National Electrical Code
OAT —
Outside Air Thermostat
BLK
L1
BLK
L2
BLK
L3
Disconnect
Power
OR
Distribution
CB
Block
(Optional)
LAR
4
3
GRY
BC
BRN
BRN
YEL
CC
BR
BRG
CCG
Test Pins
Compressor
Relay
SEE
NOTE 4
Dip Switch
FP1
1
PM
2
Not Used
FP2
Off On
Status
G
LED
JW1
C
Microprocessor
SEE NOTE 6
Control Logic
LEGEND
PM
— Performance Monitor
P1
— Field Wiring Terminal Block
RVS — Reversing Valve Solenoid
Relay Contactor Coil
Solenoid Coil
Thermistor
Ground
Field Line Voltage Wiring
Field Low Voltage Wiring
Printed Circuit Trace
Fig. 4 — Typical Aquazone™ Complete C Control Wiring
BLK
L1
BLK
T1
L2
BLK
BLK
T2
T3
L3
BLK
BLK
Compressor
CC
BLK
BLK
BLK
BLK
BLK
BLK
Blower Motor
BC
ES
+
GRY
TR1
+
BRN
TR
S
O
VIO
4
YEL
BRN
SEE
NOTE 7
8
P2
1
RED
HP
RED
2
3
BLU
LOC
BRN
4
5
GRY
FP1
GRY
6
7
VIO
FP2
VIO
8
9
BRN
RV
ORG
10
Not Used
CO
12
P3
24V
DC
EH1
EH2
CO
NOTES:
1. Compressor and blower motor thermally protected
internally.
2. All wiring to the unit must comply with NEC and
local codes.
3. 208/230 v transformers will be connected for
208 v operations. For 230 v operations, discon-
nect Red lead at L1, and attach Orange lead to
L1. Close open end of Red Lead with insulating
tape.
4. FP1 jumper provides freeze protection for
WATER. When using ANTI-FREEZE solutions, cut
FP1 jumper.
5. Typical thermostat wiring shown. Refer to thermo-
stat Installation Instructions for wiring to the unit.
6. 24 v alarm signal shown. For dry alarm contact,
cut JW1 jumper and dry contact will be available
between AL1 and AL2.
7. Transformer secondary ground via Complete C
board standoffs and screws to control box.
(Ground available from top two standoffs as
shown.)
8
WHT
115V / 1PH
GRN
Field
BLK
Wiring
GFI
(Optional)
Logic Module
MAS
(Damper Actuator)
-
GRY
BRN
BLU
600
Ohm
+
5
2
4
T1
S
R
1
3
T
2
BLK
YEL
3
YEL
CC
6
OAT
BRN
R
B
7
WHT
TAN
LAR
ECR
BRN
HP
LOC
FP1
RVS
FP2
BRN
ORG
ECR
150
Ohm
P1
P