Carrier aquazone 50RTG Installation, Start-Up And Service Instructions Manual page 12

Rooftop water source heat pump units
Table of Contents

Advertisement

SCFM
AIRFLOW
BHP
3000
RPM
Turns Out
BHP
3300
RPM
Turns Out
BHP
3600
RPM
Turns Out
BHP
4000
RPM
Turns Out
BHP
4300
RPM
Turns Out
BHP
4700
RPM
Turns Out
BHP
5000
RPM
Turns Out
LEGEND
BHP
— Brake Horsepower
SCFM — Standard Cubic Feet Per Minute
NOTES:
1. Fan BHP includes drive losses.
2. Region "A" is standard drive package.
3. Regions "B" and "C" require optional drive packages.
4. Region "D" represents oversized motor and special sheaves.
5. For applications requiring higher static pressures, contact your local representative.
SCFM
AIRFLOW
BHP
3600
RPM
Turns Out
BHP
4000
RPM
Turns Out
BHP
4400
RPM
Turns Out
BHP
4800
RPM
Turns Out
BHP
5200
RPM
Turns Out
BHP
5600
RPM
Turns Out
BHP
6000
RPM
Turns Out
LEGEND
BHP
— Brake Horsepower
SCFM — Standard Cubic Feet Per Minute
NOTES:
1. Fan BHP includes drive losses.
2. Region "A" is standard drive package.
3. Regions "B" and "C" require optional drive packages.
4. Region "D" represents oversized motor and special sheaves.
5. For applications requiring higher static pressures, contact your local representative.
Table 9 — 50RTG10 Blower Performance
0.2
0.3
0.4
0.5
0.69
0.76
0.83
0.89
563
596
628
658
4.5
B
3.5
2.5
1.5
0.89
0.96
1.03
1.10
604
635
664
693
3
2.5
1.5
4.5
1.12
1.20
1.28
1.35
647
676
703
730
A
2.0
1.0
4.5
4.0
1.47
1.56
1.64
1.73
699
725
750
775
4.5
4.0
3.5
3.0
1.82
1.90
1.99
2.09
746
770
794
817
3.5
3.0
4.5
4.5
2.32
2.42
2.52
2.61
803
825
848
869
4.5
4.0
3.5
3.5
2.76
2.86
2.96
847
868
889
3.5
3.5
3.0
Table 10 — 50RTG12 Blower Performance
0.2
0.3
0.4
0.5
1.02
1.10
1.18
1.25
609
639
667
695
5.5
4.5
3.5
2.5
B
1.38
1.45
1.54
1.62
664
691
717
742
4.5
3.0
2.0
5.5
1.77
1.86
1.96
2.05
716
741
765
789
A
2.0
5.5
4.5
4.0
2.23
2.33
2.43
2.53
765
788
810
833
5.5
4.0
3.5
3.0
2.82
2.93
3.04
3.14
825
846
867
888
4.5
2.5
5.5
5.0
3.47
3.58
3.70
3.81
879
899
918
938
5.5
5.0
4.5
4.0
4.20
4.33
4.46
4.58
933
952
970
989
4.0
3.5
3.0
3.0
EXTERNAL STATIC PRESSURE (in. wg)
0.6
0.7
0.8
0.9
0.96
1.02
1.09
1.16
688
718
746
773
1.0
4.0
3.5
3.0
1.18
1.24
1.32
1.39
721
748
775
801
4.0
3.5
3.0
2.5
1.43
1.51
1.58
1.66
756
782
807
832
3.5
2.5
2.0
1.5
1.82
1.89
1.98
2.07
799
823
847
870
2.5
2.0
4.0
3.5
2.18
2.27
2.35
2.45
840
863
885
907
4.0
3.5
3.0
2.5
2.71
2.81
2.90
891
912
933
3.0
2.5
2.0
EXTERNAL STATIC PRESSURE (in. wg)
0.6
0.7
0.8
0.9
1.33
1.41
1.49
1.56
722
748
774
800
1.5
5.5
4.5
3.5
1.71
1.78
1.87
1.96
767
792
816
839
4.5
4.0
3.5
2.5
2.13
2.23
2.32
2.41
812
835
858
879
3.5
3.0
2.0
1.5
2.63
2.73
2.83
2.93
854
876
897
918
2.5
1.5
1.0
4.5
3.25
3.36
3.47
3.58
908
928
948
968
4.5
4.0
3.5
3.5
3.93
4.04
4.16
4.27
957
976
995
1013
3.5
3.0
2.5
2.0
4.70
4.82
4.95
1007
1025
1042
2.5
2.0
1.5
12
1.0
1.1
1.2
1.3
1.22
1.29
1.36
1.43
800
826
851
876
2.5
2.0
1.5
0.5
1.46
1.54
1.62
1.69
827
852
876
900
2.0
1.0
0.5
0.0
1.75
1.83
1.90
1.99
856
880
903
926
1.0
0.5
0.0
2.5
2.16
2.24
2.33
2.42
892
915
937
958
3.0
2.5
2.0
D
1.5
2.54
2.64
2.73
2.83
929
950
971
991
2.0
1.5
1.0
1.0
Operation Not Recommended
1.0
1.1
1.2
1.3
1.64
1.72
1.80
1.88
825
849
873
896
3.0
2.5
1.5
1.0
2.05
2.13
2.22
2.31
863
886
908
930
C
2.0
1.5
4.5
4.0
2.51
2.61
2.70
2.79
901
923
944
965
5.0
4.5
4.0
3.5
3.03
3.12
3.23
3.33
938
959
978
998
4.0
3.5
D
3.0
2.5
3.69
3.78
3.89
4.00
987
1006
1025
1044
3.0
2.5
2.0
1.5
4.39
4.51
4.62
1031
1050
1067
1.5
1.5
1.0
Operation Not
Recommended
1.4
1.5
1.50
1.57
900
923
0.0
2.5
1.77
1.85
C
923
946
2.5
2.0
2.07
2.16
949
971
2.0
1.5
2.51
2.61
980
1001
1.0
0.5
2.93
1012
0.5
1.4
1.5
1.97
2.05
919
942
4.5
4.0
2.40
2.49
952
973
3.5
3.0
2.89
2.98
985
1006
3.0
2.5
3.43
3.54
1018
1037
2.0
1.5
4.11
1062
1.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents