Carrier aquazone 50RTG Installation, Start-Up And Service Instructions Manual page 11

Rooftop water source heat pump units
Table of Contents

Advertisement

SCFM
AIRFLOW
BHP
1950
RPM
Turns Out
BHP
2200
RPM
Turns Out
BHP
2400
RPM
Turns Out
BHP
2600
RPM
Turns Out
BHP
2800
RPM
Turns Out
BHP
3000
RPM
Turns Out
BHP
3250
RPM
Turns Out
LEGEND
BHP
— Brake Horsepower
SCFM — Standard Cubic Feet Per Minute
NOTES:
1. Fan BHP includes drive losses.
2. Region "A" is standard drive package.
3. Regions "B" and "C" require optional drive packages.
4. Region "D" represents oversized motor and special sheaves.
5. For applications requiring higher static pressures, contact your local representative.
SCFM
AIRFLOW
BHP
2400
RPM
Turns Out
BHP
2650
RPM
Turns Out
BHP
2900
RPM
Turns Out
BHP
3200
RPM
Turns Out
BHP
3450
RPM
Turns Out
BHP
3700
RPM
Turns Out
BHP
4000
RPM
Turns Out
LEGEND
BHP
— Brake Horsepower
SCFM — Standard Cubic Feet Per Minute
NOTES:
1. Fan BHP includes drive losses.
2. Region "A" is standard drive package.
3. Regions "B" and "C" require optional drive packages.
4. Region "D" represents oversized motor and special sheaves.
5. For applications requiring higher static pressures, contact your local representative.
Table 7 — 50RTG07 Blower Performance
0.2
0.3
0.4
0.5
0.42
0.46
0.51
0.56
620
664
707
750
B
4.5
3.5
2.5
4.5
0.56
0.62
0.67
0.73
675
716
755
793
3
2.0
4.5
3.5
0.70
0.76
0.83
0.88
721
758
795
830
A
2.0
4.5
3.5
3.0
0.87
0.94
0.99
1.06
765
800
835
868
4
3.5
3.0
2.0
1.07
1.13
1.20
1.27
812
845
877
908
3.5
2.5
2.0
1.5
1.28
1.35
1.42
1.50
857
889
919
949
2.5
1.5
1.0
0.5
1.60
1.67
1.75
1.83
915
945
974
1001
1.0
0.5
5.0
4.5
Table 8 — 50RTG08 Blower Performance
0.2
0.3
0.4
0.5
0.40
0.45
0.50
0.55
482
521
559
594
B
4.5
3.5
2.0
4.5
0.51
0.56
0.62
0.67
514
550
585
619
4
2.5
4.5
3.5
0.64
0.69
0.76
0.83
549
583
615
647
A
2.5
4.5
4.0
3.0
0.81
0.88
0.95
1.02
588
619
649
679
5
3.5
3.0
2.0
1.00
1.07
1.14
1.21
623
652
681
709
3.5
3.0
2.0
1.5
1.20
1.28
1.35
1.43
657
685
712
739
2.5
2.0
1.0
0.5
1.47
1.56
1.64
1.73
699
725
750
775
1.5
1.0
0.0
5.0
EXTERNAL STATIC PRESSURE (in. wg)
0.6
0.7
0.8
0.9
0.62
0.67
0.73
0.78
792
832
870
908
3.5
2.5
2.0
1.5
0.78
0.85
0.90
0.97
831
869
905
941
3.0
2.0
1.5
0.5
0.95
1.00
1.07
1.14
865
900
935
969
2.0
1.5
0.5
0.0
1.12
1.19
1.25
1.33
901
933
965
997
1.5
0.5
0.0
4.5
1.33
1.40
1.47
1.54
939
970
1000
1030
0.5
5.0
4.5
4.0
1.56
1.64
1.72
1.79
978
1007
1035
1064
5.0
4.5
4.0
3.5
1.90
1.98
2.06
2.13
1029
1056
1082
1109
4.0
3.5
3.0
2.5
EXTERNAL STATIC PRESSURE (in. wg)
0.6
0.7
0.8
0.9
0.61
0.66
0.72
0.77
629
661
693
723
3.5
2.5
1.5
1.0
0.74
0.79
0.86
0.91
651
683
713
742
3.0
2.0
1.0
0.5
0.88
0.95
1.01
1.08
677
707
736
764
2.0
1.5
0.5
5.0
1.09
1.16
1.23
1.30
707
735
763
789
1.5
0.5
5.0
4.5
1.29
1.36
1.44
1.52
736
763
789
814
0.5
5.0
4.5
4.0
1.51
1.60
1.67
1.75
764
790
815
839
5.0
4.5
4.0
3.5
1.82
1.89
1.98
2.07
799
823
847
870
4.5
4.0
3.5
3.0
11
1.0
1.1
1.2
1.3
Operation Not Recommended
1.03
1.10
1.17
975
1007
1038
5.0
3.0
2.5
1.21
1.28
1.34
1.41
1002
1034
1066
1097
C
4.5
4.0
3.5
3.0
1.40
1.47
1.55
1.63
1029
1060
1090
1120
4.0
3.5
3.0
2.5
1.62
1.69
1.77
1.86
1059
1089
1118
1147
3.5
3.0
2.5
2.0
1.87
1.95
2.02
2.11
1091
1119
1147
1174
3.0
2.5
2.0
1.5
2.22
2.30
2.39
2.48
1135
1161
1187
1212
2.5
2.0
1.5
1.0
1.0
1.1
1.2
1.3
0.83
0.87
0.91
0.98
751
779
806
832
0.0
4.5
4.0
3.5
0.98
1.05
1.10
1.16
770
797
823
848
4.5
4.0
3.5
3.0
1.14
1.22
1.29
1.35
791
818
843
868
4.5
4.0
3.5
3.0
C
1.38
1.45
1.52
1.60
815
841
865
890
4.0
3.5
3.0
2.5
1.60
1.67
1.75
1.83
839
863
887
911
3.5
3.0
2.5
2.0
1.84
1.91
2.00
2.08
863
886
909
932
D
3.0
2.5
2.0
1.5
2.16
2.24
2.33
2.42
892
915
937
958
2.5
2.0
1.5
1.0
1.4
1.5
1.69
1.77
1149
1178
2.0
1.5
1.94
2.01
1175
1203
1.5
1.0
2.20
2.28
1202
1228
D
1.0
1.0
2.56
2.65
1238
1263
1.0
0.5
1.4
1.5
1.03
1.10
858
883
3.0
2.5
1.21
1.27
872
895
2.5
2.0
1.42
1.49
894
915
2.5
2.0
1.67
1.74
913
936
2.0
1.5
1.90
1.99
934
956
1.5
1.0
2.17
2.26
954
976
1.0
0.5
2.51
2.61
980
1001
0.5
0.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents