Carrier aquazone 50RTG Installation, Start-Up And Service Instructions Manual page 10

Rooftop water source heat pump units
Table of Contents

Advertisement

SCFM
AIRFLOW
BHP
1300
RPM
Turns Out
BHP
1400
RPM
Turns Out
BHP
1500
RPM
Turns Out
BHP
1600
RPM
Turns Out
BHP
1700
RPM
Turns Out
BHP
1800
RPM
Turns Out
BHP
1900
RPM
Turns Out
LEGEND
BHP
— Brake Horsepower
SCFM — Standard Cubic Feet Per Minute
NOTES:
1. Fan BHP includes drive losses.
2. Region "A" is standard drive package.
3. Regions "B" and "C" require optional drive packages.
4. Region "D" represents oversized motor and special sheaves.
5. For applications requiring higher static pressures, contact your local representative.
SCFM
AIRFLOW
BHP
1700
RPM
Turns Out
BHP
1800
RPM
Turns Out
BHP
1900
RPM
Turns Out
BHP
2000
RPM
Turns Out
BHP
2100
RPM
Turns Out
BHP
2200
RPM
Turns Out
BHP
2300
RPM
Turns Out
LEGEND
BHP
— Brake Horsepower
SCFM — Standard Cubic Feet Per Minute
NOTES:
1. Fan BHP includes drive losses.
2. Region "A" is standard drive package.
3. Regions "B" and "C" require optional drive packages.
4. Region "D" represents oversized motor and special sheaves.
5. For applications requiring higher static pressures, contact your local representative.
Table 5 — 50RTG04 Blower Performance
0.1
0.2
0.3
0.4
0.26
0.30
0.33
0.36
633
694
755
812
5
3.5
4.5
3.5
B
0.33
0.36
0.40
0.43
668
725
782
836
4
3.0
4.0
3.0
0.418
0.45
0.48
0.52
712
766
819
871
3.0
4.5
3.5
2.5
0.506
0.54
0.57
0.61
750
801
851
900
4.5
3.5
3.0
2.0
0.572
0.62
0.66
0.70
792
840
887
934
4.0
3.0
2.0
1.5
0.671
0.72
0.76
0.80
832
878
923
967
3.0
2.5
1.5
1.0
0.80
0.85
0.89
0.94
875
919
961
1003
2.5
1.5
1.0
0.0
Table 6 — 50RTG05 Blower Performance
0.1
0.2
0.3
0.37
0.42
0.45
797
845
892
3.5
2.5
1.5
B
0.44
0.53
0.48
836
882
927
2.5
1.5
3.5
0.52
0.56
0.61
880
923
966
1.5
3.5
3.0
0.61
0.65
0.69
926
967
1007
3.5
3.0
2.0
0.69
0.74
0.78
966
1005
1044
3.0
2.0
1.5
0.79
0.84
0.89
1009
1047
1084
2.0
1.5
1.0
0.9
0.96
1.00
1055
1091
1126
1.0
4.5
4.0
EXTERNAL STATIC PRESSURE (in. wg)
0.5
0.6
0.7
0.40
0.42
869
925
2.5
1.5
0.46
0.50
0.53
890
943
995
2.0
1.0
0.5
0.55
0.58
0.62
922
970
1017
1.5
0.5
3.5
A
0.67
0.70
0.64
948
995
1040
C
1.0
0.0
3.5
0.74
0.78
0.81
979
1024
1068
0.5
3.5
3.0
0.85
0.89
0.94
1010
1053
1095
0.0
3.0
2.5
0.98
1.02
1.07
1045
1086
1127
3.0
2.5
2.0
EXTERNAL STATIC PRESSURE (in. wg)
0.4
0.5
0.6
0.50
0.54
0.58
938
984
1029
3.0
2.5
1.5
0.56
0.61
0.65
971
1015
1057
2.5
2.0
1.0
0.65
0.69
0.74
1008
1049
1090
2.0
A
1.5
0.5
0.74
0.78
0.84
1047
1087
1126
1.5
1.0
0.5
0.84
0.88
0.94
1082
1120
1158
1.0
0.5
0.0
0.94
0.99
1.05
1120
1157
1193
0.5
3.5
3.0
1.06
1.11
1.17
1161
1196
1231
3.5
3.0
2.5
10
0.8
0.9
Operation Not Recommended
0.65
1063
3.0
0.75
0.78
1083
1125
1.5
2.0
0.86
0.89
1110
1152
2.5
1.5
0.97
1.01
1136
1176
D
2.0
1.5
1.11
1.16
1166
1204
1.5
1.0
0.7
0.8
0.9
0.63
0.67
Operation Not
1072
1114
Recommended
1.0
0.5
0.70
0.75
0.79
1099
1140
1180
0.5
0.5
0.0
0.78
0.84
0.88
C
1131
1170
1208
0.5
0.0
3.0
0.88
0.94
0.98
1164
1203
1240
0.0
3.0
2.5
0.98
1.03
1.09
1195
1231
1268
3.0
2.5
2.0
D
1.09
1.14
1.20
1229
1264
1298
2.5
2.0
1.5
1.22
1.28
1.33
1265
1299
1332
2.0
1.5
1.0
1.0
0.83
1166
1.5
0.94
1194
1.0
1.06
1219
1.0
1.20
1242
0.5
1.0
0.94
1246
2.5
1.03
1277
2.0
1.14
1303
1.5
1.25
1333
1.0
1.39
1365
0.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents