Error Display - Furuno CI-80 Operator's Manual

Doppler sonar current indicator
Table of Contents

Advertisement

Error display

Error
Reason
number
000
Input voltage
001
Overheated transducer element
002
Abnormal Tx B voltage
003
Tx voltage of beam 1
004
Tx voltage of beam 2
005
Tx voltage of beam 3
006
Tx current of beam 1
007
Tx current of beam 2
008
Tx current of beam 3
100
External position data
101
External speed data
102
External time data
103
External depth data
104
Heading data
105
Heading error angle
106
Water temperature data
200
External KP input interval
201
Depth sensor input
202
Inclinometer roll signal
203
Inclinometer pitch signal
34
"OK" appears for normal memory IC test. For fault NG (No
Good) and asterisk (*) appear next to ROM/RAM number.
Table 3 Error number display and meaning
* Abnormally high Tx voltage, abnormally low transducer
impedance, too high Tx duty, faulty temperature sensor (faulty
element), high water temperature, and other factors may also
cause this error display.
Circuit board
to check
JCPA, JIFA
JLGA, JCPA, JIFA*
STXA, UPW, JCPA
JCPA, STXA
JCPA, STXA
JCPA, STXA
JCPA, STXA
JCPA, STXA
JCPA, STXA
JCPA, JIFA
JCPA, JIFA
JCPA, JIFA
JCPA, JIFA
JCPA, JIFA
JCPA, JIFA
JCPA, JIFA
JCPA, JIFA, abnormal external KP
interval
JLGA, JCPA, JIFA,
faulty temperature sensor
JCPA, JIFA, no inclinometer data
JCPA, JIFA, no inclinometer data

Advertisement

Table of Contents
loading