Location Of Dip Switches, Jumper Wires On The Gyro Converter Board; Setting The Heading Readout On The Radar Display - Furuno FR-2115/2125 Installation Manual

Furuno marine radar user manual
Table of Contents

Advertisement

Location of DIP switches, jumper wires on the GYRO CONVERTER
Board
JP2
(Rotor voltage)
JP3
(Stator voltage)
JP1
(Gyro type)
Fuse
(2A)
J5
(Rotor signal input,
external power input)

Setting the heading readout on the radar display

Confirm that the gyrocompass is giving a reliable readout. Then, set the heading
readout on the radar display with the gyrocompass readout as follows:
1. Press [RADAR MENU] to display the FUNCTIONS 1 menu.
2. Press the [0] key twice to display the FUNCTIONS 3 menu.
3. Press the [9] key to select the GYRO SETTING option.
4. Rotate the EBL control to align the radar's HDG readout with the gyrocompass.
5. Press [ENTER] to conclude the setting.
JP5, JP4
(Supply voltage)
SW1
J4
DIP switch
(Stator signal input)
(IEC-61162-1 output port)
Figure 4-4 GYRO CONVERTER Board
4-6
64P1106
J8
J6
(Data output port #2)
J7
(Data output port #1)
J12
(Data output
port #6)
J11
(Data output
port #5)
J10
(Data output
port #4)
SW2
DIP switch
JP6, JP7
(AD formal
data Tx interval)
J9
(Data output port #3)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-2115Fr-2125

Table of Contents