Download Print this page

Danby DAC6020 Use And Care Manual page 4

Hide thumbs Also See for DAC6020:

Advertisement

Available languages

Available languages

All wiring must comply with local and national
electrical codes and must be installed by a
qualified elecViclan. If you have any questions
regarding the following instructions, contact a
qualified electrician.
2_ Check available power supply and resolve any
wiring problems BEFORE installing and
operating this unit,
3,, This 115V air cond{fioner uses 12.0 or less
nameplate amps and may be used in any
properly wired, general purpose household
receplacle
See Table 1 for specifications for
individual branch circuit.
4, For your safely and protection, this unit is
grounded through the power cord plug when
plugged into into a matching wall outleL If
you are not sure whether your wall oulret _s
properly grounded, please consult a
qualified electrlclan.
5. The walt outlet (3-pin) must match the plug (3_
pin) on the service cord supplied with the unit.
DO NOT use plug adapters, See "Table 2 for
receptacle and fuse information° if [t fs necessary
to use an extension cord to connect your air
conditioner, use an approved "air condilfoner"
extension cord only. (available at most local
hardware stores)
6. The rating plate on the unit contains electrical
and other technical data. The rating plate
is located on the right side of the unit, above the
power cord,
Table
1:
Suggested
Individual
Branch Clrcull
Nameplate Ampa
AWG Wire Size"
5.0 to 12
14
AWG- American Wire Gage
"Based
on copper wire at 60 "C temperatore
rating..
Table
2:
Receptacle
and FuseTypes
Rated Vo_ls
125
Amps
15
Wall Oultel
Fuse Size
15
Time Delay Fuse
Plug Type
(or circuit breake0

Advertisement

loading

This manual is also suitable for:

Dac7003