6. Remount the cover assembly.
Note: Confirm that the following parts are attached:
• Inside of the cover: Shield gaskets, GN gasket (See Figure 3-17.)
• On ANLG Board:
7. Tighten nuts to torque shown below and in the order shown in Figure 3-18.
No. 1 through No. 5 : 7.5 - 8 kgf/cm
No. 6 :
8. Tighten ten binding screws (M3 x 10) fixing the cover to torque of 7.5-8 kgf/cm.
Connector gasket (See Figure 3-15.)
GN gasket
Shield gaskets
Figure 3-17 Inside of the cover
14 -16 kgf/cm
ANT
XDR
TEMP/SPD
6
2
4
Figure 3-18 Display unit, rear view
3-12
+ GND
1 3
2
-
12 - 24
DGPS
NMEA
VDC
5
1
3