Technical Specifications - Compaq R1500 - UPS - Lead Acid Specification

Specifications
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

Unit Dimensions
Unit Dimensions
Unit Dimensions
Unit Dimensions
Shipping Dimensions
Shipping Dimensions
Shipping Dimensions
Shipping Dimensions
Unit Weight
Unit Weight
Unit Weight
Unit Weight
Shipping Weight
Shipping Weight
Shipping Weight
Shipping Weight
Electrical Input
Electrical Input
Electrical Input
Electrical Input
Electrical Output
Electrical Output
Electrical Output
Electrical Output
Battery
Battery
Battery
Battery
Communications
Communications
Communications
Communications
Environmental and Safety Operating Temperature
Environmental and Safety
Environmental and Safety
Environmental and Safety
17.5 x 1.75 x 24.0 in (44.45 x 4.44 x 61 cm)
32 x 11.5 x 26.75 in (81.28 x 29.21 x 67.95 cm)
50.5 lb (22.9 kg)
76 lb (34.5 kg)
Voltage Range
Voltage Range
Voltage Range
Voltage Range
Frequency
Frequency
Frequency
Frequency
Input Plug
Input Plug
Input Plug
Input Plug
Online Efficiency
Online Efficiency
Online Efficiency
Online Efficiency
Surge Suppression
Surge Suppression
Surge Suppression
Surge Suppression
Online Regulation
Online Regulation
Online Regulation
Online Regulation
On battery Regulation
On battery Regulation
On battery Regulation
On battery Regulation
Voltage Wave Form
Voltage Wave Form
Voltage Wave Form
Voltage Wave Form
Connections
Connections
Connections
Connections
Output Protection
Output Protection
Output Protection
Output Protection
Type
Type
Type
Type
Backup Time
Backup Time
Backup Time
Backup Time
Recharge Time
Recharge Time
Recharge Time
Recharge Time
Voltage
Voltage
Voltage
Voltage
Ports
Ports
Ports
Ports
Option Slot
Option Slot
Option Slot
Option Slot
Option Cards
Option Cards
Option Cards
Option Cards
LED Indicators
LED Indicators
LED Indicators
LED Indicators
Software
Software
Software
Software
Operating Temperature
Operating Temperature
Operating Temperature
Transit Temperature
Transit Temperature
Transit Temperature
Transit Temperature
Storage Temperature
Storage Temperature
Storage Temperature
Storage Temperature
Humidity (Operation)
Humidity
Humidity
Humidity
Humidity (Non-operating) 5% to 95%
Humidity
Humidity
Humidity
Operating Altitude
Operating Altitude
Operating Altitude
Operating Altitude
Storage Altitude
Storage Altitude
Storage Altitude
Storage Altitude
Audible Noise
Audible Noise
Audible Noise
Audible Noise
Safety Markings
Safety Markings
Safety Markings
Safety Markings
Safety Certifications
Safety Certifications
Safety Certifications
Safety Certifications
EMC Markings
EMC Markings
EMC Markings
EMC Markings
Emissions
Emissions
Emissions
Emissions
Immunity
Immunity
Immunity
Immunity
Surge Suppression
Surge Suppression
Surge Suppression
Surge Suppression
DA - 14059
Worldwide — Version 2 — July 20, 2011
HP R1500 G3 Uninterruptible Power Supply (UPS)
HP R1500 G3 Uninterruptible Power Supply (UPS)
HP R1500 G3 Uninterruptible Power Supply (UPS)
HP R1500 G3 Uninterruptible Power Supply (UPS)
± 20% of nominal100, 120 and 230V models. See Model Matrix for
nominal and user selectable voltage settings via the rear panel dip switch
50/60 Hz ± 5Hz (auto sensing)
See Model Matrix
95%
High Energy 6500A peak
-10% to +6% of nominal voltage
±5% of nominal voltage
Sine wave
See Model Selection Matrix; divided into 2 Load Segments
Firmware overload sensing and control, customer supplied facility input
circuit breaker, and re-settable rear panel circuit breaker on the INTL HV
AF418A
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
See Backup Times Chart
<3 hours to 90% usable capacity; <24 hours for complete recharge
36V Battery String
Standard DB-9 port (ships with communication cable)
USB port (ships with communication cable)
One
HP UPS Network Module
LED display integrated into the front panel
HP Power Protector management software available via download
50° to 104° F (10° to 40° C)
-5° to 131° F (-15° to 55° C)
-15° to 55° F (-26° to 13° C)
5% to 95%
3000 m <35 d C; 1500 m 36 - 40 d C
<40db in normal operation; <45db while on inverter
<46db (at 1m from surface of unit)
UL/cUL ICES, GS, GOST, EK
UL1778; UL6950, CSA22.2 No.107.1,No.107.2,No.950; CB Bulletin
No.86AI; EN50091-1; EN60950
FCC-A; CISPR 22; VCCI-A; CE, BSMI, C-TICK
FCC CFR 47, Part 15 Class A, EN50091-2
IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5
Conforms to IEEE 587B and ANSI C62.41
Page 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R1500 g3

Table of Contents