Compaq 341251-002 Operation And Reference Manual

3000 series
Table of Contents

Advertisement

3000 Series UPS
Operation and Reference Guide
Second Edition (October 1999)
Part Number 341251-002
Compaq Computer Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Compaq 341251-002

  • Page 1 3000 Series UPS Operation and Reference Guide Second Edition (October 1999) Part Number 341251-002 Compaq Computer Corporation...
  • Page 2 MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, GOOD TITLE AND AGAINST INFRINGEMENT. This publication contains information protected by copyright. No part of this publication may be photocopied or reproduced in any form without prior written consent from Compaq Computer Corporation. © 1999 Compaq Computer Corporation.
  • Page 3: Table Of Contents

    Compaq Technical Support .................xi Compaq Website ....................xi Compaq Authorized Reseller................xii Chapter 1 Overview Compaq 3000 Series UPS Models................1-2 Front Panels ......................1-3 Rear Panels ......................1-4 Standard UPS Features .................... 1-8 Communications Port ..................1-9 Power Management Software................1-9 Hardware Option Cards ..................
  • Page 4 Compaq 3000 Series UPS Operation and Reference Guide Chapter 2 Installation Installation Requirements ..................2-2 Item(s) not supplied with the UPS kit............... 2-2 Item(s) supplied with the UPS kit ..............2-2 Before Starting the UPS................... 2-3 Rack Mounting the UPS ................... 2-4 Connecting to the Communications Port ............
  • Page 5 About This Guide v Chapter 5 Battery Maintenance Precautions....................... 5-2 Charging Batteries ....................5-3 When to Replace Batteries..................5-3 Pre-Failure Battery Warranty................... 5-4 Obtaining New Batteries..................5-4 Replacing Batteries....................5-4 Step 1: Preparing the UPS ................5-5 Step 2: Removing the Battery Pack ..............5-5 Step 3: Installing New Batteries ...............
  • Page 6 Compaq 3000 Series UPS Operation and Reference Guide Appendix C Specifications Physical Specifications ................... C-2 Input Specifications ....................C-3 Output Specifications....................C-4 Output Specifications....................C-5 Overcurrent Protection.................... C-6 Battery Specifications ..................... C-7 Battery Runtime ...................... C-8 Environmental Specifications ................. C-9...
  • Page 7: About This Guide

    About This Guide This guide is designed to be used as step-by-step instructions for installation and as a reference for operation, troubleshooting, and future upgrades. Text Conventions This document uses the following conventions to distinguish elements of text: Keys Keys appear in boldface. A plus sign (+) between two keys indicates that they should be pressed simultaneously.
  • Page 8: Symbols In Text

    Compaq 3000 Series UPS Operation and Reference Guide Symbols in Text These symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life.
  • Page 9: Precautions

    WARNING: There is a risk of electric shock from high earth conductor leakage current when connecting multiple pieces of Information Technology Equipment to Compaq 3000 Series Uninterruptible Power Systems (UPS): The summation of the input power for multiple pieces of Information Technology Equipment through the use of a UPS can result in high earth conductor leakage current.
  • Page 10: Rack Stability

    Compaq 3000 Series UPS Operation and Reference Guide WARNING: The 3000 Series UPS models weigh 132 lb (60 kg) when fully assembled. To reduce the risk of personal injury or damage to the equipment: Observe local occupational health and safety requirements and guidelines for manual material handling.
  • Page 11: Getting Help

    Operating system type and revision level Detailed, specific questions Compaq Website The Compaq website has information on this product as well as the latest drivers and Flash ROM images. You can access the Compaq website at: http://www.compaq.com For continuous quality improvement, calls may be recorded or monitored.
  • Page 12: Compaq Authorized Reseller

    Compaq 3000 Series UPS Operation and Reference Guide Compaq Authorized Reseller For the name of your nearest Compaq authorized reseller: In the United States, call 1-800-345-1518. In Canada, call 1-800-263-5868. Elsewhere, access the Compaq website at: http://www.compaq.com...
  • Page 13: Overview

    Chapter Overview This chapter contains information on the following topics: Compaq 3000 Series Uninterruptible Power System (UPS) models 3000 Series UPS front panels 3000 Series UPS rear panels 3000 Series UPS features Warranties...
  • Page 14: Compaq 3000 Series Ups Models

    1-2 Compaq 3000 Series UPS Operation and Reference Guide Compaq 3000 Series UPS Models The Compaq 3000 Series includes the following UPS models: Table 1-1 3000 Series UPS Models UPS Model Part Number Comments R3000 242705-001 Domestic; low voltage; Rack-mountable...
  • Page 15: Front Panels

    Overview 1-3 Front Panels The 3000 Series UPS models are rack-mountable. Figure 1-1. Front panel configuration Battery compartment Control buttons LED display Air vents...
  • Page 16: Rear Panels

    1-4 Compaq 3000 Series UPS Operation and Reference Guide Rear Panels The 3000 Series UPS models feature the following rear panel configurations: Figure 1-2. Rear panel of R3000 Load segment 1 Option slot Load segment 2 REPO port Load segment 3...
  • Page 17 Overview 1-5 Figure 1-3. Rear panel of R3000j Load segment 1 Option slot Load segment 2 REPO port Load segment 3 Power cord with L6-30p plug Communications port Output circuit breakers...
  • Page 18 1-6 Compaq 3000 Series UPS Operation and Reference Guide Figure 1-4. Rear panel of R3000h Load segment 3 Option slot Load segment 2 REPO port Load segment 1 Input/Output circuit breakers Communications port IEC-320-C19 16A power inlet...
  • Page 19 Overview 1-7 Figure 1-5. Rear panel of R3000h-International Load segment 3 Option slot Load segment 2 REPO port Load segment 1 Input/Output circuit breakers Communications port Power cord with IEC-309 15A plug...
  • Page 20: Standard Ups Features

    1-8 Compaq 3000 Series UPS Operation and Reference Guide Figure 1-6. Rear panel of R3000h-NA Load segment 3 Option slot Load segment 2 REPO port Load segment 1 Input/Output circuit breakers Communications port Power cord with L6-30p plug Standard UPS Features...
  • Page 21: Communications Port

    The power management software supplied by Compaq enables the user to access status reporting and power management features. CAUTION: Use only cables supplied by Compaq to connect the communications port to the host computer. Use of standard RS-232 cables may cause equipment damage.
  • Page 22: Hardware Option Cards

    After saving the necessary information, completing the orderly device shutdown. For more information on using Compaq Power Management Software, refer to the Compaq Power Products Software Reference Guide section of the Power Products Documentation CD (included with the UPS kit).
  • Page 23: Remote Emergency Power Off (Repo) Port

    Using the SNMP-EN Internal Adapter SNMP communication interface, system administrators can quickly ascertain if power-related problems exist anywhere on the network. A Compaq UPS, connected by an SNMP-EN Internal Adapter to power management software, can virtually eliminate costly downtime due to power outages or surges, and decrease day-to-day network management annoyances like spontaneous rebooting, lost files and corrupted data—issues resulting from inconsistent power.
  • Page 24: Warranties

    Warranties $25,000 Computer Load Protection Guarantee To back up the wide range of features offered with the UPS, Compaq provides a three-year limited warranty. In addition, Compaq offers a $25,000 Computer Load Protection Guarantee (provided by the original equipment manufacturer).
  • Page 25: Pre-Failure Battery Warranty

    Compaq Power Management Software that the battery may fail, the battery is replaced free of charge under the warranty. Compaq maintains the highest standards in the industry, as evidenced by the Compaq Pre-Failure Battery Warranty. The Pre-Failure Battery Warranty is...
  • Page 26: Installation

    Chapter Installation This chapter provides information on the following topics: Installation requirements Procedures to complete before starting the UPS Starting the UPS Completing the installation...
  • Page 27: Installation Requirements

    2-2 Compaq 3000 Series UPS Operation and Reference Guide Installation Requirements This section lists items needed to install the Compaq 3000 Series UPS models. Item(s) not supplied with the UPS kit Tools A medium flat-bladed and Phillips screwdriver may be needed.
  • Page 28: Before Starting The Ups

    6-foot, IEC to IEC power cords, Compaq part number 142263-001; two 8-foot IEC to IEC power cords, Compaq part number 142263-002; and two 10-foot IEC to IEC power cords, Compaq part number 142263-003, for load equipment power. All models ship with a computer interface cable. The computer interface cable is not needed for normal operation.
  • Page 29: Rack Mounting The Ups

    2-4 Compaq 3000 Series UPS Operation and Reference Guide Rack Mounting the UPS The 3000 Series UPS models must be mounted on fixed rails. Refer to the appropriate installation card (supplied with the UPS kit) to obtain instructions. WARNING: The 3000 Series UPS models weigh 132 lb (60 kg). To reduce the...
  • Page 30: Connecting To The Communications Port

    The 3000 Series UPS models include a communications port for data exchange with the host computer. IMPORTANT: Compaq Power Management Software, LanSafe III, and FailSafe III require the communications port to be appropriately cabled to the host computer. Connect the UPS/computer interface cable (supplied) from the communications port on the UPS to the appropriate communications port on the host computer.
  • Page 31 2-6 Compaq 3000 Series UPS Operation and Reference Guide Use this procedure to activate the REPO port: 1. Install a suitable switch at the required remote location. 2. Remove the connector block from the REPO port. Figure 2-2. Removing the connector block 3.
  • Page 32: Starting The Ups

    IMPORTANT: Do not use the UPS if the battery recharge date has expired. If the date on the Battery Recharge Date label has passed without the batteries being recharged, contact an Authorized Compaq Service Representative. THIS PRODUCT CONTAINS A NONSPILLABLE BATTERY...
  • Page 33: Connecting The Ups To Utility Power

    CAUTION: Do not plug laser printers into the UPS. The instantaneous current drawn by this type of printer may overload the UPS. IMPORTANT: To provide additional receptacles, plug a Compaq Power Distribution Unit (PDU) into the high current receptacle associated with load segments 1, 2, or 3. To...
  • Page 34: Powering Up The Ups

    Installation 2-9 Powering up the UPS When the unit is plugged in for the first time, the UPS automatically initiates a self-test. The front panel LED display lights will go on and off during the self- test. If the self-test is completed successfully, the UPS enters Standby mode. NOTE: The self-test initiates when the UPS is plugged in for the first time.
  • Page 35: Completing The Installation

    With the UPS in Standby mode, allow the batteries to charge before putting the UPS into service. IMPORTANT: The batteries will charge to 90% of their capacity within approximately 4 hours. Compaq recommends allowing the batteries to charge for 24 hours before using them to supply backup power to devices.
  • Page 36: Placing The Ups In Operate Mode

    ON button The Installation is Now Complete For information on operating the UPS, see Chapter 3, “Operation.” For information on changing the configuration of the UPS, see Chapter 4, “Configuration.” Use the Compaq website as an additional information source: http://www.compaq.com...
  • Page 37: Operation

    Chapter Operation This chapter contains information on the following topics: Precautions to be observed when using the UPS UPS modes of operation Front panel controls Front panel indicators Overcurrent protection Placing the UPS in Operate mode Returning to Standby mode Initiating a self-test The audio alarm...
  • Page 38: Precautions

    3-2 Compaq 3000 Series UPS Operation and Reference Guide Precautions Observe these precautions when using the Compaq 3000 Series UPS models. WARNING: To reduce the risk of electric shock from earth conductor leakage current: Do not operate a UPS that is disconnected from the utility power source.
  • Page 39: Front Panel Controls

    Operation 3-3 Sleep Mode By default, Sleep mode is disabled. When Sleep mode is disabled: If the batteries have been fully discharged, power may not be automatically restored to the output receptacles when utility power is restored. CAUTION: The UPS Sleep mode default setting is OFF (disabled). When Sleep mode is OFF (disabled), if the UPS is supplying battery power, the batteries can be fully discharged before the UPS will shut down.
  • Page 40 3-4 Compaq 3000 Series UPS Operation and Reference Guide The front panel includes the following LED indicators and button controls: 13 12 11 Figure 3-1. The front panel LED display and controls Symbol 1–4 AC Input level Power cord Site Wiring Fault indicator 6–9...
  • Page 41: Front Panel Indicators

    Operation 3-5 Front Panel Indicators The front panel LED display colors indicate the UPS status: Green LEDs indicate normal conditions Red LEDs provide warning of existing or potential problems LEDs are referred to as LED 1 through 16, as described in this documentation. When the UPS is in Configure mode, the LEDs do not operate as they do in the Standby and Operate modes (see Chapter 4, “Configuration”).
  • Page 42 3-6 Compaq 3000 Series UPS Operation and Reference Guide Site Wiring Fault (LED 5) Table 3-2 Site Wiring Fault LED Color Meaning No ground connection between utility power and the UPS. The line and neutral connections between utility power and the UPS are reversed.
  • Page 43 Operation 3-7 Load Level (LEDs 11-14) Table 3-5 Load Level LEDs Color Meaning Load on the UPS exceeds the maximum power available. Green Load on the UPS is approximately 67% to 100% of the maximum power available. (LEDs 13 and 14 are also green) Green Load on the UPS is approximately 66% of the maximum power available.
  • Page 44: Overcurrent Protection

    3-8 Compaq 3000 Series UPS Operation and Reference Guide Overcurrent Protection Overcurrent protection is provided via resettable circuit breakers located on the rear panel. The following models have overcurrent protection: Table 3-7 Overcurrent Protection UPS Model Device R3000 Circuit breaker for each load segment...
  • Page 45: Placing The Ups In Operate Mode

    Operation 3-9 Placing the UPS in Operate Mode The Compaq 3000 Series UPS may be placed in Operate mode if either of the following conditions apply: The UPS is powered up and in Standby mode (LED 16 is off) The UPS is powered off; no utility power is available Press and hold the ON button (2) until the LED 16 (ON LED 1) turns green, indicating that power is available at the UPS output receptacles.
  • Page 46: Returning To Standby Mode

    3-10 Compaq 3000 Series UPS Operation and Reference Guide Returning to Standby Mode When the UPS is in Operate mode (LED 16, 1, is green), pressing the STANDBY button (2) will place the UPS in Standby mode. The UPS will acknowledge compliance with a short beep.
  • Page 47: Initiating A Self-Test

    Operation 3-11 Initiating a Self-test To initiate a self-test, press the TEST/ALARM RESET button and hold for three seconds. The UPS acknowledges compliance with five beeps. Figure 3-4. The TEST/ALARM RESET button TEST/ALARM RESET button IMPORTANT: A portion of the self-test requires battery power; the self-test cannot be initiated if the batteries are less than 90% charged.
  • Page 48: Audio Alarm

    3-12 Compaq 3000 Series UPS Operation and Reference Guide Audio Alarm The UPS may sound an audio alarm to warn the user that an alarm condition exists. IMPORTANT: Certain audio alarms can be disabled. See Chapter 4, “Configuration,” for more information.
  • Page 49 Operation 3-13 IMPORTANT: Even though an audio alarm may be silenced, the condition that caused the alarm may still exist. For information on procedures to follow if the UPS detects an alarm condition, see Chapter 6, “Troubleshooting.” If a utility power failure caused the alarm (AC Input LED 1 or LED 4 red), the alarm will be silenced after utility power is restored.
  • Page 50: Configuration

    Chapter Configuration This chapter contains information on the following topics: Placing the UPS in Configure mode Configuration parameters and their LED indicators Using the front panel LED display and controls to monitor and change configuration parameters Using the UPS configuration parameters to optimize battery life by matching utility voltage...
  • Page 51: Placing The Ups In Configure Mode

    4-2 Compaq 3000 Series UPS Operation and Reference Guide Placing the UPS in Configure Mode The Compaq 3000 Series UPS can enter the Configure mode while in the Operate or Standby mode. Figure 4-1. Configure mode controls ON LED (LED 16)
  • Page 52: Configuration Parameters And Their Led Indicators

    Configuration 4-3 Configuration Parameters and their LED Indicators In the Configure mode, the front panel LEDs 1 to 15 are assigned to eleven configuration parameters , detailed in the following table. (LED 16 indicates the ON or OFF status of each parameter.) 13 12 11 Figure 4-2.
  • Page 53 4-4 Compaq 3000 Series UPS Operation and Reference Guide Table 4-1 Configuration Parameters/LED Indicators Parameter Parameter LED 16 Explanation (LED) Name Status 120/230 Nom Nominal utility voltage level is 120/230 VAC. (Default for R3000, R3000h, and R3000h-Int) 110/220 Nom Nominal utility voltage level is 110/220 VAC.
  • Page 54 Configuration 4-5 Table 4-1 Configuration Parameters/LED Indicators continued Parameter Parameter LED 16 Explanation (LED) Name Status Shutdown Enables a 5-second delay before turning Delay (default) off power to the output receptacles after receiving a shutdown command from the host. Enables a 3-minute delay. AC Input Failure Enables an audio alarm when the utility (default)
  • Page 55: Changing Configuration Parameters

    4-6 Compaq 3000 Series UPS Operation and Reference Guide Changing Configuration Parameters The Configure mode may be entered from the Operate or Standby mode. IMPORTANT: If the STANDBY button is pressed while in the Configure mode, the UPS will enter Standby mode, and power to the load segments will cease.
  • Page 56: Optimizing Battery Life By Matching The Utility Voltage

    Configuration 4-7 4. To toggle the selected configuration parameter value, press the TEST/ALARM RESET button (4). The UPS will acknowledge compliance with a short beep. NOTE: For nominal voltage configuration parameters 1, 2, 3, and 10—selecting an ON value for any one parameter automatically sets the other three possibilities to OFF. 5.
  • Page 57 4-8 Compaq 3000 Series UPS Operation and Reference Guide Operating Range Upper Limit Nominal Lower Limit Utility Voltage Time Figure 4-4. Optimal—Utility voltage fluctuating within the UPS operating range Operating Range + 20% Nominal - 20% Utility Voltage Time Figure 4-5. Utility voltage fluctuation indicating a shift in nominal voltage...
  • Page 58 Configuration 4-9 Operating Range +20% Extended Nominal Range - 20% -35% Utility Voltage Time Figure 4-6. Utility voltage fluctuation indicating a possible need for extended range setting To match the utility voltage, the UPS operating range can be modified in two ways: If the utility voltage differs from the currently configured nominal voltage, but stays within a ±20% band (see Fig 4-5), consider shifting...
  • Page 59 4-10 Compaq 3000 Series UPS Operation and Reference Guide Table 4-2 Operating Ranges (VAC) – North America and Japanese Models Nominal Level Normal Range Extended Range 80 to 120 Not applicable for R3000j 88 to 132 72 to 132 96 to 144...
  • Page 60: Battery Maintenance

    Chapter Battery Maintenance This chapter contains information on the following topics: Precautions to be observed when maintaining or replacing batteries Charging batteries When to replace batteries Pre-Failure Battery Warranty Obtaining new batteries Replacing batteries Care and storage of batteries...
  • Page 61: Precautions

    UPS batteries. The maintenance and replacement of batteries must be carried out by qualified service personnel. Replace the batteries with the Compaq spare designated for the UPS. The spare battery kit part number is 295462-001. WARNING: The UPS contains sealed lead-acid batteries. To reduce the risk of fire or chemical burns take the following precautions: Do not attempt to recharge batteries after removal from the UPS.
  • Page 62: Charging Batteries

    Battery Maintenance 5-3 Charging Batteries The Compaq 3000 Series UPS models automatically charge the batteries when connected to utility power. No user intervention is required while the UPS is in use. For information on charging the batteries when installing the UPS, see “Completing the Installation”...
  • Page 63: Pre-Failure Battery Warranty

    Compaq Power Management Software that the battery may fail, the battery is replaced free of charge under the warranty. Compaq maintains the highest standards in the industry, as evidenced by the Compaq Pre-Failure Battery Warranty. The Pre-Failure Battery Warranty is...
  • Page 64: Step 1: Preparing The Ups

    Battery Maintenance 5-5 Step 1: Preparing the UPS To replace batteries with the UPS Off 1. Shut down all load devices. 2. Press the STANDBY button to take the UPS out of Operate mode. The ON LED extinguishes, and power to the load receptacles ceases. 3.
  • Page 65 5-6 Compaq 3000 Series Operation and Reference Guide Figure 5-2. Removing the faceplate 2. Disconnect the LED display cable from the faceplate, and set the faceplate aside, exercising care to avoid damaging the printed circuit board behind the LED display.
  • Page 66 Battery Maintenance 5-7 3. Remove two screws to access the battery pack. Figure 5-4. Accessing the battery pack 4. Slide the battery pack partially out of the UPS chassis to access the battery terminals. Figure 5-5. Partially removing the battery pack...
  • Page 67 5-8 Compaq 3000 Series Operation and Reference Guide 5. Disconnect the negative (black) battery pack terminal connections. WARNING: To reduce the risk of short-circuits or arcing, disconnect the negative (black) battery lead before disconnecting the positive (red) battery lead. Figure 5-6. Disconnecting the battery pack terminal connections 6.
  • Page 68: Step 3: Installing New Batteries

    Battery Maintenance 5-9 WARNING: The 3000 Series battery pack weighs 60 lb. Prepare the area and observe all materials handling procedures for removing the battery pack. 8. Carefully slide the battery pack out only until the second plastic handle is accessible. Figure 5-8.
  • Page 69 5-10 Compaq 3000 Series Operation and Reference Guide Figure 5-9. Replacing the battery cable retainer bracket Battery cables Battery cable retainer bracket 2. Reconnect the battery cable terminal connectors, positive (+, red lead) first. WARNING: To reduce the risk of short-circuits or arcing, connect the positive (red) battery lead before connecting the negative (black) battery lead.
  • Page 70: Step 4: Testing New Batteries

    Battery Maintenance 5-11 4. Reinstall the faceplate. Attach the LED display cable to the LED display, aligning the two alignment pins on the smooth side of the connector with the slots at the bottom of the receptacle. Figure 5-10. Reattaching the LED display cable Faceplate attachment slots 5.
  • Page 71: Step 5: Disposing Of Used Batteries

    5-12 Compaq 3000 Series Operation and Reference Guide If the installation has not been successful, the Battery Service indicator (LED 10) will turn red. If this occurs, check the battery terminal connections. If the Battery Service indicator is still red, see Chapter 6, “Troubleshooting,”...
  • Page 72: Troubleshooting

    Chapter Troubleshooting This chapter provides information on the following topics: Troubleshooting problems that occur during UPS start Troubleshooting problems that occur after start Repairing the UPS...
  • Page 73: Troubleshooting During Start

    6-2 Compaq 3000 Series UPS Operation and Reference Guide Troubleshooting During Start If problems occur when starting the Compaq 3000 Series UPS models, select the appropriate symptom for possible causes and actions suggested. Table 6-1 Troubleshooting Guide (UPS Start) Symptom...
  • Page 74: Troubleshooting After Start

    Troubleshooting 6-3 Troubleshooting After Start For problems that occur after the UPS has gone through the startup self-test sequence, these suggested actions address possible causes. Table 6-2 Troubleshooting Guide (After Start) Symptom Possible Cause Suggested Action Audio Alarm Alarm condition exists Identify the red LED associated with this alarm condition.
  • Page 75 6-4 Compaq 3000 Series UPS Operation and Reference Guide Table 6-2 Troubleshooting Guide (After Start) continued Symptom Possible Cause Suggested Action Utility power variations The utility voltage is frequently frequently outside the UPS operating range. switches Update the configuration. between...
  • Page 76: Repairing The Ups

    Shut down the UPS. Contact an flashing red; exists authorized service provider. audio alarm cannot be silenced Repairing the UPS Repairs to the UPS must be carried out by Compaq or a Compaq Authorized Service Provider. Other than battery replacement, there are no user-serviceable parts.
  • Page 77: Regulatory Compliance Notices

    Appendix Regulatory Compliance Notices Federal Communications Commission Notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules.
  • Page 78: Class A Equipment

    A-2 Compaq 3000 Series Operation and Reference Guide Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 79: Modifications

    Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Compaq Computer Corporation may void the user's authority to operate the equipment. Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
  • Page 80: Class B Equipment

    A-4 Compaq 3000 Series Operation and Reference Guide Class B Equipment This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
  • Page 81: Japanese Notice

    Your UPS is provided with a Sealed Lead Acid battery pack. There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by a Compaq Authorized Service Provider using the Compaq spare designated for this product. For more information about battery replacement or proper disposal, contact your Compaq authorized reseller or your Authorized Service Provider.
  • Page 82 Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water. Replace only with the Compaq spare designated for this product. Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. In order...
  • Page 83: Electrostatic Discharge

    Appendix Electrostatic Discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices.
  • Page 84: Grounding Methods

    B-2 Compaq 3000 Series UPS Operation and Reference Guide Grounding Methods There are several methods for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis.
  • Page 85: Appendix C Specifications

    Appendix Specifications This appendix provides specifications that apply to Compaq 3000 Series UPS models: Physical specifications Input specifications Output specifications Overcurrent protection Battery specifications Battery runtime Environmental specifications...
  • Page 86: Physical Specifications

    C-2 Compaq 3000 Series UPS Operation and Reference Guide Physical Specifications Table C-1 Physical Specifications – 3000 Series UPS Models Feature U.S. Metric Dimensions Width 19.0 in 483 mm Height 5.25 in 133 mm Depth 22.3 in 566 mm Weight...
  • Page 87: Input Specifications

    Specifications C-3 Input Specifications Table C-2 Input Specifications – 3000 Series UPS Models UPS Model Utility Voltage Nominal Utility Power Cord Supplied Frequency (Hz) Voltage (VAC) R3000 Non-detachable cord with L5-30p plug 100, 110 120, 127 R3000j Non-detachable cord with L6-30p plug 100, 110 120, 127 R3000h...
  • Page 88: Output Specifications

    C-4 Compaq 3000 Series UPS Operation and Reference Guide Output Specifications Table C-3 Output Specifications – 3000 Series UPS Models UPS Model Nominal Power Load Segment # Output Receptacles Rating (VA) R3000 2880 3 x 5-15R 3 x 5-15R 3 x 5-15R...
  • Page 89 Specifications C-5 Table C-4 Output Specifications – 3000 Series UPS Models Characteristics Utility Voltage (VAC) Nominal Output Voltage (VAC) Voltage 110 to 127 220 to 240 Source of Power Regulation ±8% of nominal output voltage rating Output Utility power (normal range) (within the guidelines of the Computer Business Equipment Manufacturers Association)
  • Page 90: Overcurrent Protection

    C-6 Compaq 3000 Series UPS Operation and Reference Guide Overcurrent Protection Table C-5 Overcurrent Protection - Per Model UPS Model Input Protection R3000 Circuit breaker for each load segment R3000j Circuit breaker for each load segment R3000h Input circuit breaker...
  • Page 91: Battery Specifications

    Specifications C-7 Battery Specifications Table C-6 Battery Specifications – 3000 Series UPS Models Feature Specification Type Sealed lead-acid; maintenance-free Voltage Internal batteries – 48 VDC Charging 3 to 8 hours to full charge Less than 3 hours to 90% capacity at default nominal utility voltage and no load...
  • Page 92: Battery Runtime

    C-8 Compaq 3000 Series UPS Operation and Reference Guide Battery Runtime Table C-7 Estimated Battery Runtime Load (VA) Battery Runtime (Minutes) 1000 1200 1400 1500 1800 2000 2200 2400 3000 If a device list the power in Watts, use the following conversion equation:...
  • Page 93: Environmental Specifications

    Specifications C-9 Environmental Specifications Table C-8 Environmental Specifications – 3000 Series UPS Models Feature Specification Operating temperature to 40 C (32 to 104 UL-tested at 25 C (77 Relative humidity 0% to 95%; non-condensing Operating altitude Up to 3000 m (10,000 ft) above sea level Audible noise Less than 45 dBA...
  • Page 94: Index

    Index Numbers and Symbols 3000 Series UPS See batteries Uninterruptible Power System care and storage See care and 3000 Series storage of batteries changing See also replacing batteries procedure 5-4 AC Input Failure warning on rack stability 5-2 disabling audio alarm 4-5 warning on weight 5-2 AC Input LEDs warning to use qualified service...
  • Page 95 2 Compaq 3000 Series UPS Operation and Reference Guide Communication LED, recommendation against keeping explained 3-7 spares 5-4 communications port when to obtain 5-4 caution on communications replacing See replacing cables 2-5 batteries caution on use of suitable runtime specifications C-8...
  • Page 96 3000 Series UPS 1-8 parameters 4-3 audio alarm 3-12 Reset Defaults, restoring 4-5 communications port 1-9 Shutdown Delay enabling 3- Compaq OnliNet Centro 1-9 minute 4-5 Compaq Power Management Shutdown Delay enabling 5- Software 1-9 second 4-5 FailSafe III 1-9...
  • Page 97 4 Compaq 3000 Series UPS Operation and Reference Guide meaning in Configure connecting the communications mode 4-6 port 2-5 meaning of green LEDs 3-5 connecting the devices 2-8 meaning of LED display in connecting the REPO port See Standby and Operate...
  • Page 98 See Standby option card mode, Operate mode, Configure Compaq Multi-Server UPS mode, Sleep mode Card example of use 1-10 overview 1-10 Compaq Scalable UPS Card nominal utility voltage level example of use 1-11 explained 4-4 overview 1-10 related configuration parameters 4-4...
  • Page 99 6 Compaq 3000 Series UPS Operation and Reference Guide Compaq SNMP-EN Internal Power Management Software See Adapter Compaq Power Management example of use 1-11 Software overview 1-11 Power Products Documentation CD overview 1-10 viewing protecting multiple Compaq 3000 Series Operation...
  • Page 100 Index 7 disconnecting the faceplate, self-test illustrated 5-6 initiating See TEST/ALARM disposing of used RESET button batteries 5-12 meaning of LED display 3-11 hot swapping 5-5 requirement for 90%-charged installing new batteries 5-9 batteries 3-11 options 5-4 serial port See communications partially removing the battery port pack, illustrated 5-7...
  • Page 101 8 Compaq 3000 Series UPS Operation and Reference Guide switching the UPS off See updating the UPS STANDBY button configuration 4-2, 4-6, 4-7 symbols in text viii UPS/computer interface cable symbols on equipment viii connecting from the UPS to the...

Table of Contents