Compaq Presario 3000 Series Operation And Reference Manual

Compaq operation and reference guide ups 3000 series
Hide thumbs Also See for Presario 3000 Series:
Table of Contents

Advertisement

Operation and Reference Guide
Second Edition (October 1999)
Part Number 341251-002
Compaq Computer Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Compaq Presario 3000 Series

  • Page 1 Operation and Reference Guide Second Edition (October 1999) Part Number 341251-002 Compaq Computer Corporation...
  • Page 2 MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, GOOD TITLE AND AGAINST INFRINGEMENT. This publication contains information protected by copyright. No part of this publication may be photocopied or reproduced in any form without prior written consent from Compaq Computer Corporation. © 1999 Compaq Computer Corporation.
  • Page 3: Table Of Contents

    Getting Help ...x Compaq Technical Support ...xi Compaq Website...xi Compaq Authorized Reseller...xi Chapter 1 Overview Compaq 3000 Series UPS Models... 1-2 Front Panels ... 1-3 Rear Panels ... 1-4 Standard UPS Features ... 1-8 Communications Port ... 1-9 Power Management Software... 1-9 Hardware Option Cards ...
  • Page 4 Compaq 3000 Series UPS Operation and Reference Guide Chapter 2 Installation Installation Requirements ... 2-2 Item(s) not supplied with the UPS kit ... 2-2 Item(s) supplied with the UPS kit ... 2-2 Before Starting the UPS... 2-3 Rack Mounting the UPS ... 2-4 Connecting to the Communications Port ...
  • Page 5 Chapter 5 Battery Maintenance Precautions... 5-2 Charging Batteries ... 5-3 When to Replace Batteries... 5-3 Pre-Failure Battery Warranty... 5-4 Obtaining New Batteries... 5-4 Replacing Batteries... 5-4 Step 1: Preparing the UPS ... 5-5 Step 2: Removing the Battery Pack ... 5-5 Step 3: Installing New Batteries ...
  • Page 6 Compaq 3000 Series UPS Operation and Reference Guide Appendix C Specifications Physical Specifications ...C-2 Input Specifications...C-3 Output Specifications...C-4 Output Specifications...C-5 Overcurrent Protection...C-6 Battery Specifications ...C-7 Battery Runtime ...C-8 Environmental Specifications ...C-9 Index...
  • Page 7: About This Guide

    This guide is designed to be used as step-by-step instructions for installation and as a reference for operation, troubleshooting, and future upgrades. Text Conventions This document uses the following conventions to distinguish elements of text: Keys USER INPUT FILENAMES Menu Options, Command Names, Dialog Box Names COMMANDS,...
  • Page 8: Symbols In Text

    Compaq 3000 Series UPS Operation and Reference Guide Symbols in Text These symbols may be found in the text of this guide. They have the following meanings. IMPORTANT: Text set off in this manner presents clarifying information or specific instructions.
  • Page 9: Precautions

    WARNING: There is a risk of electric shock from high earth conductor leakage current when connecting multiple pieces of Information Technology Equipment to Compaq 3000 Series Uninterruptible Power Systems (UPS): The summation of the input power for multiple pieces of Information Technology Equipment through the use of a UPS can result in high earth conductor leakage current.
  • Page 10: Rack Stability

    Compaq 3000 Series UPS Operation and Reference Guide IMPORTANT: Please refer to the UPS kit) before installing this product. Rack Stability Getting Help If you have a problem and have exhausted the information in this guide, you can get further information and other help in the following locations.
  • Page 11: Compaq Technical Support

    Operating system type and revision level Detailed, specific questions Compaq Website The Compaq website has information on this product as well as the latest drivers and Flash ROM images. You can access the Compaq website at: http://www.compaq.com Compaq Authorized Reseller For the name of your nearest Compaq authorized reseller: In the United States, call 1-800-345-1518.
  • Page 12: Overview

    Chapter Overview This chapter contains information on the following topics: Compaq 3000 Series Uninterruptible Power System (UPS) models 3000 Series UPS front panels 3000 Series UPS rear panels 3000 Series UPS features Warranties...
  • Page 13: Compaq 3000 Series Ups Models

    1-2 Compaq 3000 Series UPS Operation and Reference Guide Compaq 3000 Series UPS Models The Compaq 3000 Series includes the following UPS models: UPS Model R3000 R3000j R3000h R3000h-Int R3000h-NA Front Panels The 3000 Series UPS models are rack-mountable. Figure 1-1. Front panel configuration...
  • Page 14: Rear Panels

    Rear Panels The 3000 Series UPS models feature the following rear panel configurations: Figure 1-2. Rear panel of R3000 Load segment 1 Load segment 2 Load segment 3 Communications port Option slot REPO port Power cord with L5-30p plug Output circuit breakers Overview 1-3...
  • Page 15 1-4 Compaq 3000 Series UPS Operation and Reference Guide Figure 1-3. Rear panel of R3000j Load segment 1 Load segment 2 Load segment 3 Communications port Figure 1-4. Rear panel of R3000h Load segment 3 Load segment 2 Load segment 1...
  • Page 16 Figure 1-5. Rear panel of R3000h-International Load segment 3 Option slot Load segment 2 REPO port Load segment 1 Input/Output circuit breakers Communications port Power cord with IEC-309 15A plug Overview 1-5...
  • Page 17: Standard Ups Features

    1-6 Compaq 3000 Series UPS Operation and Reference Guide Figure 1-6. Rear panel of R3000h-NA Load segment 3 Load segment 2 Load segment 1 Communications port Standard UPS Features The 3000 Series UPS models provide the following features: Communications port for data exchange with the host computer...
  • Page 18: Communications Port

    The power management software supplied by Compaq enables the user to access status reporting and power management features. CAUTION: Use only cables supplied by Compaq to connect the communications port to the host computer. Use of standard RS-232 cables may cause equipment damage.
  • Page 19: Hardware Option Cards

    After saving the necessary information, completing the orderly device shutdown. For more information on using Compaq Power Management Software, refer to the Compaq Power Products Software Reference Guide section of the Power Products Documentation CD (included with the UPS kit).
  • Page 20 Compaq Scalable UPS Card The Scalable UPS Card makes up to three UPS units appear as a single virtual UPS to the host computer and, with Compaq Power Management Software, allows scaling up the level of power protection available to the system.
  • Page 21: Remote Emergency Power Off (Repo) Port

    Using the SNMP-EN Internal Adapter SNMP communication interface, system administrators can quickly ascertain if power-related problems exist anywhere on the network. A Compaq UPS, connected by an SNMP-EN Internal Adapter to power management software, can virtually eliminate costly downtime due to power outages or surges, and decrease day-to-day network management annoyances like spontaneous rebooting, lost files and corrupted data—issues resulting from inconsistent power.
  • Page 22: Warranties

    Warranties $25,000 Computer Load Protection Guarantee To back up the wide range of features offered with the UPS, Compaq provides a three-year limited warranty. In addition, Compaq offers a $25,000 Computer Load Protection Guarantee (provided by the original equipment manufacturer).
  • Page 23 Chapter Installation This chapter provides information on the following topics: Installation requirements Procedures to complete before starting the UPS Starting the UPS Completing the installation...
  • Page 24: Installation Requirements

    2-2 Compaq 3000 Series UPS Operation and Reference Guide Installation Requirements This section lists items needed to install the Compaq 3000 Series UPS models. Item(s) not supplied with the UPS kit Tools A medium flat-bladed and Phillips screwdriver may be needed.
  • Page 25: Before Starting The Ups

    6-foot, IEC to IEC power cords, Compaq part number 142263-001; two 8-foot IEC to IEC power cords, Compaq part number 142263-002; and two 10-foot IEC to IEC power cords, Compaq part number 142263-003, for load equipment power. All models ship with a computer interface cable. The computer interface cable is not needed for normal operation.
  • Page 26: Rack Mounting The Ups

    2-4 Compaq 3000 Series UPS Operation and Reference Guide Rack Mounting the UPS The 3000 Series UPS models must be mounted on fixed rails. Refer to the appropriate installation card (supplied with the UPS kit) to obtain instructions. WARNING: The 3000 Series UPS models weigh 132 lb (60 kg). To reduce the...
  • Page 27: Connecting To The Communications Port

    The 3000 Series UPS models include a communications port for data exchange with the host computer. IMPORTANT: Compaq Power Management Software, LanSafe III, and FailSafe III require the communications port to be appropriately cabled to the host computer. Connect the UPS/computer interface cable (supplied) from the communications port on the UPS to the appropriate communications port on the host computer.
  • Page 28 2-6 Compaq 3000 Series UPS Operation and Reference Guide Use this procedure to activate the REPO port: 1. Install a suitable switch at the required remote location. 2. Remove the connector block from the REPO port. Figure 2-2. Removing the connector block 3.
  • Page 29: Starting The Ups

    IMPORTANT: Do not use the UPS if the battery recharge date has expired. If the date on the Battery Recharge Date label has passed without the batteries being recharged, contact an Authorized Compaq Service Representative. THIS PRODUCT CONTAINS A NONSPILLABLE BATTERY...
  • Page 30: Connecting The Ups To Utility Power

    After verifying that the UPS will not overload, connect the power cords from the devices to the appropriate output receptacles of the UPS. IMPORTANT: To provide additional receptacles, plug a Compaq Power Distribution Unit (PDU) into the high current receptacle associated with load segments 1, 2, or 3. To connect the devices to the PDU, use IEC-320 jumper cords (part number 295633-B21).
  • Page 31: Powering Up The Ups

    Powering up the UPS When the unit is plugged in for the first time, the UPS automatically initiates a self-test. The front panel LED display lights will go on and off during the self- test. If the self-test is completed successfully, the UPS enters Standby mode. NOTE: The self-test initiates when the UPS is plugged in for the first time.
  • Page 32: Completing The Installation

    UPS into service. IMPORTANT: The batteries will charge to 90% of their capacity within approximately 4 hours. Compaq recommends allowing the batteries to charge for 24 hours before using them to supply backup power to devices. ) should be off, indicating that no power is...
  • Page 33: Placing The Ups In Operate Mode

    The Installation is Now Complete For information on operating the UPS, see Chapter 3, “Operation.” For information on changing the configuration of the UPS, see Chapter 4, “Configuration.” Use the Compaq website as an additional information source: http://www.compaq.com STANDBY button Installation 2-11...
  • Page 34: Operation

    Chapter Operation This chapter contains information on the following topics: Precautions to be observed when using the UPS UPS modes of operation Front panel controls Front panel indicators Overcurrent protection Placing the UPS in Operate mode Returning to Standby mode Initiating a self-test The audio alarm...
  • Page 35: Precautions

    3-2 Compaq 3000 Series UPS Operation and Reference Guide Precautions Observe these precautions when using the Compaq 3000 Series UPS models. Modes of Operation The 3000 Series UPS models have four modes of operation: Standby Mode No power is available at the UPS output receptacles.
  • Page 36: Front Panel Controls

    Sleep Mode By default, Sleep mode is disabled. When Sleep mode is disabled: If the batteries have been fully discharged, power may not be automatically restored to the output receptacles when utility power is restored. CAUTION: The UPS Sleep mode default setting is OFF (disabled). When Sleep mode is OFF (disabled), if the UPS is supplying battery power, the batteries can be fully discharged before the UPS will shut down.
  • Page 37 3-4 Compaq 3000 Series UPS Operation and Reference Guide The front panel includes the following LED indicators and button controls: Figure 3-1. The front panel LED display and controls – – – AC Input level Site Wiring Fault indicator Battery Charge level...
  • Page 38: Front Panel Indicators

    Front Panel Indicators The front panel LED display colors indicate the UPS status: Green LEDs indicate normal conditions Red LEDs provide warning of existing or potential problems LEDs are referred to as LED 1 through 16, as described in this documentation. When the UPS is in Configure mode, the LEDs do not operate as they do in the Standby and Operate modes (see Chapter 4, “Configuration”).
  • Page 39 3-6 Compaq 3000 Series UPS Operation and Reference Guide Site Wiring Fault (LED 5) Note: For units factory-configured for 208V, the Site Wiring Fault function has been disabled. If reconfiguring a 230V unit to operate at 208V, the Site Wiring Fault function must be manually disabled.
  • Page 40 Load Level (LEDs 11-14) Table 3-5 Load Level LEDs Color Load on the UPS exceeds the maximum power available. Green Load on the UPS is approximately 67% to 100% of the maximum power available. (LEDs 13 and 14 are also green) Green Load on the UPS is approximately 66% of the maximum power available.
  • Page 41: Overcurrent Protection

    3-8 Compaq 3000 Series UPS Operation and Reference Guide Overcurrent Protection Overcurrent protection is provided via resettable circuit breakers located on the rear panel. The following models have overcurrent protection: Table 3-7 Overcurrent Protection UPS Model R3000 Circuit breaker for each load segment...
  • Page 42: Placing The Ups In Operate Mode

    Placing the UPS in Operate Mode The Compaq 3000 Series UPS may be placed in Operate mode if either of the following conditions apply: The UPS is powered up and in Standby mode (LED 16 is off) The UPS is powered off; no utility power is available Press and hold the ON button ( ) until the LED 16 (ON LED indicating that power is available at the UPS output receptacles.
  • Page 43: Returning To Standby Mode

    3-10 Compaq 3000 Series UPS Operation and Reference Guide Returning to Standby Mode When the UPS is in Operate mode (LED 16, STANDBY button ( ) will place the UPS in Standby mode. The UPS will acknowledge compliance with a short beep. LED 16 ( ) will extinguish, and power to the loads will cease.
  • Page 44: Initiating A Self-Test

    Initiating a Self-test To initiate a self-test, press the TEST/ALARM RESET button and hold for three seconds. The UPS acknowledges compliance with five beeps. Figure 3-4. The TEST/ALARM RESET button TEST/ALARM RESET button IMPORTANT: A portion of the self-test requires battery power; the self-test cannot be initiated if the batteries are less than 90% charged.
  • Page 45: Audio Alarm

    3-12 Compaq 3000 Series UPS Operation and Reference Guide Audio Alarm The UPS may sound an audio alarm to warn the user that an alarm condition exists. IMPORTANT: Certain audio alarms can be disabled. See Chapter 4, “Configuration,” for more information.
  • Page 46 Operation 3-13 IMPORTANT: Even though an audio alarm may be silenced, the condition that caused the alarm may still exist. For information on procedures to follow if the UPS detects an alarm condition, see Chapter 6, “Troubleshooting.” If a utility power failure caused the alarm (AC Input LED 1 or LED 4 red), the alarm will be silenced after utility power is restored.
  • Page 47: Configuration

    Chapter Configuration This chapter contains information on the following topics: Placing the UPS in Configure mode Configuration parameters and their LED indicators Using the front panel LED display and controls to monitor and change configuration parameters Using the UPS configuration parameters to optimize battery life by matching utility voltage...
  • Page 48: Placing The Ups In Configure Mode

    4-2 Compaq 3000 Series UPS Operation and Reference Guide Placing the UPS in Configure Mode The Compaq 3000 Series UPS can enter the Configure mode while in the Operate or Standby mode. Figure 4-1. Configure mode controls ON LED (LED 16)
  • Page 49: Configuration Parameters And Their Led Indicators

    Configuration Parameters and their LED Indicators In the Configure mode, the front panel LEDs 1 to 15 are assigned to eleven configuration parameters the ON or OFF status of each parameter.) Figure 4-2. The front panel LED display and controls Configuration parameters 11 to 14 are reserved for future use.
  • Page 50 4-4 Compaq 3000 Series UPS Operation and Reference Guide Parameter (LED) Table 4-1 Configuration Parameters/LED Indicators Parameter LED 16 Name Status 120/230 Nom Nominal utility voltage level is 120/230 VAC. (Default for R3000, R3000h, and R3000h-Int) 110/220 Nom Nominal utility voltage level is 110/220 VAC.
  • Page 51 Table 4-1 Configuration Parameters/LED Indicators Parameter Parameter LED 16 (LED) Name Status Shutdown Delay (default) AC Input Failure (default) Sleep Mode (default) 11-14 Reserved Reset Defaults Notes: Only one nominal utility voltage can be configured. If model R3000j voltage defaults to 120, change the voltage to 100. If model R3000h-NA voltage defaults to 230, change the voltage to 208.
  • Page 52: Changing Configuration Parameters

    4-6 Compaq 3000 Series UPS Operation and Reference Guide Changing Configuration Parameters The Configure mode may be entered from the Operate or Standby mode. IMPORTANT: If the STANDBY button is pressed while in the Configure mode, the UPS will enter Standby mode, and power to the load segments will cease.
  • Page 53: Optimizing Battery Life By Matching The Utility Voltage

    4. To toggle the selected configuration parameter value, press the TEST/ALARM RESET button ( ). The UPS will acknowledge compliance with a short beep. NOTE: For nominal voltage configuration parameters 1, 2, 3, and 10—selecting an ON value for any one parameter automatically sets the other three possibilities to OFF. 5.
  • Page 54 4-8 Compaq 3000 Series UPS Operation and Reference Guide Nominal Figure 4-4. Optimal—Utility voltage fluctuating within the UPS operating range Nominal Figure 4-5. Utility voltage fluctuation indicating a shift in nominal voltage range may be necessary Operating Range Upper Limit...
  • Page 55 Operating Range Nominal Utility Voltage Time Figure 4-6. Utility voltage fluctuation indicating a possible need for extended range setting To match the utility voltage, the UPS operating range can be modified in two ways: If the utility voltage differs from the currently configured nominal voltage, but stays within a ±20% band (see Fig 4-5), consider shifting the nominal voltage parameter selection to match the measured utility voltage range.
  • Page 56 4-10 Compaq 3000 Series UPS Operation and Reference Guide Operating Ranges (VAC) – North America and Japanese Models Nominal Level Nominal Level 3. For nominal voltage level setting, select configuration parameters 1, 2, 3, or 10 (see Table 4-1). 4. Access parameter 4 to switch from normal to extended range (see Table 4-1).
  • Page 57: Battery Maintenance

    Chapter Battery Maintenance This chapter contains information on the following topics: Precautions to be observed when maintaining or replacing batteries Charging batteries When to replace batteries Pre-Failure Battery Warranty Obtaining new batteries Replacing batteries Care and storage of batteries...
  • Page 58: Precautions

    UPS batteries. The maintenance and replacement of batteries must be carried out by qualified service personnel. Replace the batteries with the Compaq spare designated for the UPS. The spare battery kit part number is 295462-001. WARNING: The UPS contains sealed lead-acid batteries. To reduce the risk of fire or chemical burns take the following precautions: Do not attempt to recharge batteries after removal from the UPS.
  • Page 59: Charging Batteries

    Charging Batteries The Compaq 3000 Series UPS models automatically charge the batteries when connected to utility power. No user intervention is required while the UPS is in use. For information on charging the batteries when installing the UPS, see “Completing the Installation” in Chapter 2, “Installation.”...
  • Page 60: Pre-Failure Battery Warranty

    Compaq Power Management Software that the battery may fail, the battery is replaced free of charge under the warranty. Compaq maintains the highest standards in the industry, as evidenced by the Compaq Pre-Failure Battery Warranty. The Pre-Failure Battery Warranty is...
  • Page 61: Step 1: Preparing The Ups

    Step 1: Preparing the UPS To replace batteries with the UPS Off 1. Shut down all load devices. 2. Press the STANDBY button to take the UPS out of Operate mode. The ON LED extinguishes, and power to the load receptacles ceases. 3.
  • Page 62 5-6 Compaq 3000 Series Operation and Reference Guide Figure 5-2. Removing the faceplate 2. Disconnect the LED display cable from the faceplate, and set the faceplate aside, exercising care to avoid damaging the printed circuit board behind the LED display.
  • Page 63 Battery Maintenance 5-7 3. Remove two screws to access the battery pack. Figure 5-4. Accessing the battery pack 4. Slide the battery pack partially out of the UPS chassis to access the battery terminals. Figure 5-5. Partially removing the battery pack...
  • Page 64 5-8 Compaq 3000 Series Operation and Reference Guide 5. Disconnect the negative (black) battery pack terminal connections. Figure 5-6. Disconnecting the battery pack terminal connections 6. Disconnect the positive (red) battery pack terminal connections. 7. Slide the battery pack out approximately 6 inches, to access the battery cable retainer bracket.
  • Page 65: Step 3: Installing New Batteries

    WARNING: The 3000 Series battery pack weighs 60 lb. Prepare the area and observe all materials handling procedures for removing the battery pack. 8. Carefully slide the battery pack out only until the second plastic handle is accessible. Figure 5-8. Sliding the battery pack out to reveal the second handle 9.
  • Page 66 5-10 Compaq 3000 Series Operation and Reference Guide Figure 5-9. Replacing the battery cable retainer bracket Battery cables 2. Reconnect the battery cable terminal connectors, positive (+, red lead) first. IMPORTANT: The first inch of each positive battery cable is reinforced with a black material.
  • Page 67: Step 4: Testing New Batteries

    4. Reinstall the faceplate. Attach the LED display cable to the LED display, aligning the two alignment pins on the smooth side of the connector with the slots at the bottom of the receptacle. Figure 5-10. Reattaching the LED display cable Faceplate attachment slots 5.
  • Page 68: Step 5: Disposing Of Used Batteries

    5-12 Compaq 3000 Series Operation and Reference Guide Step 5: Disposing of Used Batteries The spare battery kit includes the instructions and packaging required to return used batteries to the appropriate location for disposal. Care and Storage of Batteries To maximize the life of batteries: Minimize the amount of time the UPS uses battery power by matching UPS configuration with utility voltage.
  • Page 69: Troubleshooting

    Chapter Troubleshooting This chapter provides information on the following topics: Troubleshooting problems that occur during UPS start Troubleshooting problems that occur after start Repairing the UPS...
  • Page 70: Troubleshooting During Start

    6-2 Compaq 3000 Series UPS Operation and Reference Guide Troubleshooting During Start If problems occur when starting the Compaq 3000 Series UPS models, select the appropriate symptom for possible causes and actions suggested. Symptom UPS will not start LED 5 is red...
  • Page 71: Troubleshooting After Start

    Troubleshooting After Start For problems that occur after the UPS has gone through the startup self-test sequence, these suggested actions address possible causes. Troubleshooting Guide (After Start) Symptom Possible Cause Audio Alarm Alarm condition exists LED 1 is red Utility voltage is too high (Input Power) LED 1 is Alarm may need to be reset...
  • Page 72 6-4 Compaq 3000 Series UPS Operation and Reference Guide Table 6-2 Troubleshooting Guide (After Start) Symptom frequently switches between utility and battery power LED 11 is red (Load Level) LED 9 is red (Battery Charge) Insufficient warning of low batteries...
  • Page 73: Repairing The Ups

    Repairing the UPS Repairs to the UPS must be carried out by Compaq or a Compaq Authorized Service Provider. Other than battery replacement, there are no user-serviceable parts. Troubleshooting 6-5 continued Suggested Action Allow batteries to charge for 24 hours, then initiate self-test.
  • Page 74: Regulatory Compliance Notices

    Regulatory Compliance Notices Federal Communications Commission Notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules.
  • Page 75: Class A Equipment

    A-2 Compaq 3000 Series Operation and Reference Guide Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 76: Modifications

    Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Compaq Computer Corporation may void the user’s authority to operate the equipment. Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
  • Page 77: Canadian Notice (Avis Canadien

    A-4 Compaq 3000 Series Operation and Reference Guide Canadian Notice (Avis Canadien) Class A Equipment This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
  • Page 78: Japanese Notice

    Regulatory Compliance Notices A-5 Japanese Notice July 14 version Taiwanese Notice...
  • Page 79: Battery Replacement Notice

    Your UPS is provided with a Sealed Lead Acid battery pack. There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by a Compaq Authorized Service Provider using the Compaq spare designated for this product. For more information about battery replacement or proper disposal, contact your Compaq authorized reseller or your Authorized Service Provider.
  • Page 80: Appendix B Electrostatic Discharge

    Electrostatic Discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices.
  • Page 81: Grounding Methods

    B-2 Compaq 3000 Series UPS Operation and Reference Guide Grounding Methods There are several methods for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis.
  • Page 82: Appendix C Specifications

    This appendix provides specifications that apply to Compaq 3000 Series UPS models: Physical specifications Input specifications Output specifications Overcurrent protection Battery specifications Battery runtime Environmental specifications Appendix Specifications...
  • Page 83: Physical Specifications

    C-2 Compaq 3000 Series UPS Operation and Reference Guide Physical Specifications Dimensions Weight Input Specifications UPS Model R3000 R3000j R3000h R3000h-Int R3000h-NA Table C-1 Physical Specifications – 3000 Series UPS Models Feature Width Height Depth Table C-2 Input Specifications – 3000 Series UPS Models...
  • Page 84: Output Specifications

    Output Specifications Output Specifications – 3000 Series UPS Models UPS Model R3000 R3000j R3000h R3000h-Int R3000h-NA Table C-3 Nominal Power Load Segment # Rating (VA) 2880 2880 2880 Specifications C-3 Output Receptacles 3 x 5-15R 3 x 5-15R 3 x 5-15R 1 x L5-30R 3 x 5-15R 3 x 5-15R...
  • Page 85: Output Specifications

    C-4 Compaq 3000 Series UPS Operation and Reference Guide Characteristics Voltage Output Other features Table C-4 Output Specifications – 3000 Series UPS Models Utility Voltage (VAC) Nominal Output Voltage (VAC) 110 to 127 220 to 240 Source of Power Utility power...
  • Page 86: Overcurrent Protection

    Overcurrent Protection Overcurrent Protection - Per Model UPS Model R3000 R3000j R3000h R3000h-Int R3000h-NA Battery Specifications Battery Specifications – 3000 Series UPS Models Feature Type Voltage Charging Table C-5 Input Protection Circuit breaker for each load segment Circuit breaker for each load segment Input circuit breaker Circuit breaker for each load segment Input circuit breaker...
  • Page 87: Battery Runtime

    C-6 Compaq 3000 Series UPS Operation and Reference Guide Battery Runtime If a device list the power in Watts, use the following conversion equation: Volts x Amps = VA per device If only Watts are given: Watts x 1.35 = VA...
  • Page 88: Environmental Specifications

    Specifications C-7 Environmental Specifications Table C-8 Environmental Specifications – 3000 Series UPS Models Feature Specification Operating temperature to 40 C (32 to 104 UL-tested at 25 C (77 Relative humidity 0% to 95%; non-condensing Operating altitude Up to 3000 m (10,000 ft) above sea level Audible noise Less than 45 dBA...
  • Page 89: Index

    Numbers and Symbols 3000 Series UPS See Uninterruptible Power System 3000 Series AC Input Failure disabling audio alarm 4-5 AC Input LEDs explained 3-5 meaning when UPS powered up 2-10 troubleshooting alarm conditions 6-3 alarm See audio alarm audio alarm ability to disable 3-12 conditions causing an alarm 3-12...
  • Page 90 2 Compaq 3000 Series UPS Operation and Reference Guide recommendation against keeping spares 5-4 when to obtain 5-4 replacing See replacing batteries runtime specifications C-8 spare part number 5-2, 5-4 specifications C-7 testing 5-11 Battery Charge LEDs display explained 2-10...
  • Page 91 Index 3 using the UPS communication port 2-5 features 3000 Series UPS 1-8 audio alarm 3-12 communications port 1-9 Compaq OnliNet Centro 1-9 Compaq Power Management Software 1-9 FailSafe III 1-9 front panel 1-3 LanSafe III 1-9 option card 1-10...
  • Page 92 4 Compaq 3000 Series UPS Operation and Reference Guide getting help xi Grounding Methods B-2 guarantee See warranties hardware option card See option card help additional sources xi Compaq authorized resellers xi Compaq website xi technical support telephone numbers xi...
  • Page 93 3-2 option card Compaq Multi-Server UPS Card example of use 1-10 overview 1-10 Compaq Scalable UPS Card example of use 1-11 overview 1-10 Compaq SNMP-EN Internal Adapter example of use 1-11 overview 1-11 overview 1-10...
  • Page 94 6 Compaq 3000 Series UPS Operation and Reference Guide LanSafe III 1-9 operating the UPS 3-1 option card 1-10 Remote Emergency Power Off 1-11 specifications C-1 troubleshooting 6-1 UPS 1-1 physical characteristics C-2 physical specifications C-2 power cord cords shipped with the...
  • Page 95 STANDBY button symbols in text viii symbols on equipment viii system administrator specifying the shutdown sequence 1-10 using Compaq Power Management Software 1-9 technical support xi telephone numbers xii TEST/ALARM RESET button exiting Configure mode 4-7 initiating a self-test 3-11...
  • Page 96 8 Compaq 3000 Series UPS Operation and Reference Guide Uninterruptible Power System 3000 Series features 1-8 front panel 1-3 illustrated 1-3 items not supplied with UPS kit 2-2 items supplied with UPS kit 2-2 models 1-2 overview 1-1 rear panels, illustrated 1-4...

This manual is also suitable for:

800 series3000 series

Table of Contents